4
O P E R A T I O N
4-13
V8.5e Rev 2.2.2002
Grayscale media table number
t1 - media calibration table for media 1.
t2 - media calibration table for media 2.
These tables have preset values for imaging on two different medias
while in grayscale mode. These medias can be changed for different
medias by uploading new tables.
Setup headers for programming the V8.5e
NOTE:
The V8.5E must be in PRINT mode for the setup
header string to work. Numeric values shown below
are hexadecimal, not ASCII.
NOTE:
All menu functions can be remotely configured by
sending a setup header string from the host to the
V8.5E through the interface. The programmable
advance past TOF can be programmed in a similar
fashion.
NOTE:
Sending a 00 hex in any of the setup string positions
listed below allows the menu item to remain
unchanged.
The format is as follows:
Byte 1:
escape code
=99
Byte 2:
contrast
C1=11
Lightest
C2=12
C3=13
C4=14
C5=15
C6=16
C7=17
C8=18 Darkest
No Change=00