SERVICE INFORMATION 00 – 19
MAGNETIC SWITCH CONTACTS ARE
FUSED AND NOT MOVED, OR A
RETURN SPRING IS BROKEN OR
DETERIORATED
NO
STARTER DOES NOT STOP THOUGH STARTER
SWITCH IS RETURNED TO “ON” FROM “START”
REPLACE STARTER SWITCH
DISCONNECTED STARTER SWITCH WIRING CONNECTOR, AND CHECK STARTER SWITCH OPERATION.
KEY
POSITION
BATTERY
B1
IGNITION
IG1
BATTERY
B2
ACCESSORIES
ACC
IGNITION
IG2
STARTER
ST
LOCK
OFF
ACC
ON
START
THERE MUST BE NO CONTINUITY EXCEPT ABOVE LINES.
YES
REPLACE MAGNETIC SWITCH