PERIODIC MAINTENANCE
79
Perform the following maintenance every 500 hours
of operation.
• Replace air cleaner element
• Replace fuel filter (element)
• Clean water separator
■
Replace air cleaner element
NOTICE
The maximum air intake restriction, in terms of
differential pressure measurement, must not
exceed 0.90 PSI (6.23 kPa; 635 mmAq). Clean or
replace the air cleaner element if the air intake
restriction exceeds the above mentioned value.
Replace the air cleaner element (Figure 13, (2))
every 500 hours even if it is not damaged or dirty.
When replacing the element, clean the inside of the
air cleaner case (Figure 13, (4)).
If the air cleaner is equipped with a double element,
only remove and replace the inner element
(Figure 14, (1)) if the engine lacks power or the
dust indicator actuates (if equipped). This is in
addition to replacing the outer element.
■
Replace fuel filter (element)
DANGER
Fire and Explosion Hazard!
• Diesel fuel is flammable and
explosive under certain
conditions.
• When you remove any fuel system component
to perform maintenance (such as changing
the fuel filter) place an approved container
under the opening to catch the fuel.
• Never use a shop rag to catch the fuel. Vapors
from the rag are flammable and explosive.
• Wipe up any spills immediately.
• Wear eye protection. The fuel system is under
pressure and fuel could spray out when you
remove any fuel system component.
• Failure to comply will result in death or
serious injury.
NOTICE
For maximum engine life, Isuzu recommends that
when shutting the engine down, you allow the
engine to idle, without load, for five minutes. This
will allow the engine components that operate at
high temperatures, such as the turbocharger (if
equipped) and exhaust system, to cool slightly
before the engine itself is shut down.
NOTICE
• Always be environmentally
responsible.
• Follow the guidelines of the EPA or other
governmental agencies for the proper disposal of
hazardous materials such as engine oil, diesel
fuel and engine coolant. Consult the local
authorities or reclamation facility.
• Never dispose of hazardous materials
irresponsibly by dumping them into a sewer, on
the ground, or into ground water or waterways.
• Failure to follow these procedures may seriously
harm the environment.
Every 500 Hours of Operation
TNV_OperationManual_T4(under 19kW).book Page 79 Wednesday, June 17, 2015 11:23 AM