General Information 0A-53
Propeller Shaft Sliding Yoke, Universal
Joint
• Multi purpose grease containing molybdenum
disulfide.
Engine Cooling System
When using Isuzu genuine long-life coolant (LLC), the
percentage of LLC in the coolant should be 30 to 60%.
If it is more than 60%, overheating is likely to occur,
while if it is less than 30%, the coolant’s anti corrosion
performance will be inadequate.
Use a 30% LLC and 60% water mixture for moderate
outside temperatures.
Anti-freeze solution concentration and freezing
temperature
Select the mixture ratio for a freezing temperature that
is about 10
°
C (50
°
F) lower than the expected outside
temperature.
When using an anti-freeze solution other than the Isuzu
genuine LLC (Isuzu specified product), use the
following mixture ratios;
When the outside temperature is above -40
°
C (-40
°
F):
50% anti-freeze solution and 50% tap water
When the outside temperature is -40
°
C (-40
°
F) or
lower: 60% anti-freeze solution and 40% tap water
MAKE
BRAND
GRADE
API
ACEA
JASO
ISUZU GENUINE
ONE LUBER MO GREASE
Caltex
Molytex Grease EP2 (No.2)
Shell
Retinax HDX2 (No.2)
MAKE
BRAND
ISUZU GENUINE
BESCO LLC SUPER TYPE E, AS
Caltex/Texaco/Chevron
Extended Life Coolant
Caltex/Texaco/Chevron
Havoline XLC
Caltex/Texaco/Chevron
Delo XLC
MFU8Z0SH042501
0
20
40
60
80 100
0
-10
-20
-30
-40
-50
32
14
-4
-22
-40
-58
Anti-freeze solution
concentration(%)
(°F)(°C)
Freezing
temperature
LGGEN-WE-0871_7th.book 53
ページ
2009年10月1日 木曜日 午後3時26分
mechanikar
Summary of Contents for 2008 N Series
Page 1: ...WORKSHOP MANUAL GENERAL INFORMATION No LGGEN WE 0871 m e c h a n i k a r...
Page 3: ...LGGEN WE 0871 Maegaki 08 7 3 3 38 PM 2 m e c h a n i k a r...
Page 71: ...62013 LGGEN WE 0871 09 9 10 1 12 PM 2 m e c h a n i k a r...
Page 72: ...WORKSHOP MANUAL GENERAL INFORMATION No LGGEN WE 0871 m e c h a n i k a r...