IST Dolphin Tech JT-30 Owner'S Manual Download Page 6

1) 

 

Make sure this o-ring  us present in the male end of the 
low pressure BC hose 

 
2) 

Screw the hose into a 

low pressure port in your regulator’s first stage. 

 

 

 
3) 

Pull back the quick disconnect sleeve in the female end of the low pressure BC hose and connect 
it to the power inflator’s quick disconnect nipple.   

 

 
4) 

Open the tank valve SLOWLY. Check for any air leakage and proper power inflator function before   
using the air cell.

 

 
 

Over-pressure exhaust valve 

 

 

You  can  conveniently  pull  open 

the over-pressure exhaust valve 

to  vent  gas  in  the  bladder  to 

change  your  buoyancy  while 

diving.  As  with  the  power 

inflator

’s  deflation  button,  it 

needs to be at the highest point 

of  the  air  cell  in  order  to  be 

effective. 

 

Summary of Contents for Dolphin Tech JT-30

Page 1: ...TECHNICAL DIVING COMPONENT 30lbf AIR CELL Item no JT 30 50lbf AIR CELL Item no JT 50 65lbf EXP AIR CELL Item no JT 65 EN1809 1997 0120 Printed in Taiwan Ver E991007H...

Page 2: ...0 and twin 15 litre tanks for JT 65 air cell Do not use this air cell as a lift bag It is not designed for this purpose and may result in uncontrollable ascent which could lead to serious injury or ev...

Page 3: ...re It has a back up 19 inflator hose which is attached to a secondary back up bladder Each bladder also has 2 over pressure exhaust valves for convenience in buoyancy control The position of the valve...

Page 4: ...dder from bursting All air cells come with a 16 long assembly comprises of a power inflator corrugated hose and standard technical elbow connection For JT 65 an additional back up 19 long assembly is...

Page 5: ...ving with the power inflator make sure the inflator elbow is at the highest point i e above the rest of the wing and hold the power inflator as high as you possible can before depressing the button Or...

Page 6: ...t it to the power inflator s quick disconnect nipple 4 Open the tank valve SLOWLY Check for any air leakage and proper power inflator function before using the air cell Over pressure exhaust valve You...

Page 7: ...ll gently shake then turn the air cell upside down so it can be rinsed thoroughly Drain some water through the inflator mouthpiece then the rest through the over pressure valve s Repeat 2 to 3 times I...

Page 8: ...kmanship for the period of 2 years from the date of purchase Proper maintenance as prescribed in this manual is required to uphold the warranty during valid coverage period Any wear and tear under nor...