THERMAL CONDITIONS 

           

The ISP XMAX112 Sub Series is capable of producing 1000 watts at full power.  This generates 
heat that must be dissipated in order to maintain reliability and insure the amplifier components 
stay within their operating temperature specs.  To accomplish this, the amplifier is mounted onto 
a heatsink that requires air movement at the rear of the cabinet.  It is recommended that the rear 
of the cabinet have at least 6 inches of clearance from any obstruction to allow proper ventilation 
to occur.  
  
The  internal  amplifier  is  cooled  with  a  small  fan.    The  XMAX112  is  designed  such  that  the 
temperature should never exceed a level where the global thermal protection becomes active.  If 
the  internal  fan  fails  or  the  ventilation  system  is  blocked  so  that  airflow  is  impeded  the  global 
thermal  protect  may  activate,  which  will  attenuate  the  signal  40db  when  the  temperature 
exceeds  a  preset  point.    When  the  temperature  drops  below  a  certain  point,  full  signal  will  be 
restored.    Tests  have  shown  under  extreme  conditions  that  cycling  will  occur  (40  sec.  ON,  20 
sec. OFF).  If the global thermal protection becomes active, determine the cause for the lack of 
proper cooling.  Correcting the problem will allow the XMAX112 to continue correct operation.  
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Xmax 112

Page 1: ...1 ...

Page 2: ...gn objects or liquid into this unit This active speaker system has an internal amplifier and a heatsink located inside the back of the cabinet with an internal fan for cooling of the internal amplifier Care should be taken to avoid placing this active speaker in a location where the fan in blocked and does not allow proper cooling of the internal amplifier Avoid placing this system close to other ...

Page 3: ...e to noise levels in excess of 90db may cause permanent hearing loss Below is a chart of the OSHA Occupational Safety Health Administration regulations for Occupational Noise Exposure Please note OSHA requires hearing protection for any work environment when the sound levels exceed those shown in Table G 16 when measured on the A scale of a standard sound level meter at slow response ...

Page 4: ... temperature protection global limiting and transformer thermal protection The XMAX112 offers XLR balanced inputs and XLR balanced full range and High Pass outputs allowing connections for multiple speakers in a system A sensitivity adjustment knob allows you to adapt the XMAX112 speaker for a wide range of common signal levels The XMAX112 subwoofer cabinet is made of high quality 13 ply Baltic bi...

Page 5: ...ll control the phase of the input signal feeding the internal amplifier but is configured to by pass the crossover for the XMAX112 subwoofer This will allow the use of an external crossover to configure the system This switch will not affect any of the balanced outputs 6 INPUT SENSITIVITY This control determines the overall input level of the signal to the power amp section of the subwoofer cabine...

Page 6: ...he fuse cover module after it is pulled out NOTE A SMALL COMPARTMENT IS ALSO PROVIDED WITHIN THE FUSE COVER MODULE FOR STORING A SPARE FUSE 2 After replacing the fuse with another of identical specifications push the fuse cover module fully back into place ensuring that the fuse has snapped onto the fuse holder inside the power inlet module ...

Page 7: ...7 CONNECTION DIAGRAM ...

Page 8: ...igured to AES standards Audio Engineering Society These connections are connected in a loop through configuration from the inputs to the full range outputs and will accept a balanced line level input The standard phase configuration is that pin 2 is pin 3 is and pin 1 is shielded ground on the XLR ...

Page 9: ...resetting Transformer has internal thermal fuse self resetting Transducer Low Frequency Transducer Diameter 1x12 Voice Coil Diameter 4 76 2mm Power Handling 500 watts RMS each D CAT Technology Power Amplifier Low Frequency Amplifier Power Output 1400 watts RMS THD 0 06 typical Line Input Power Voltage 120VAC 60 Hz Current 10 amps max 5 amps typical Power 1400 watts Physical Height 35 8 Front Width...

Page 10: ...rnal amplifier is cooled with a small fan The XMAX112 is designed such that the temperature should never exceed a level where the global thermal protection becomes active If the internal fan fails or the ventilation system is blocked so that airflow is impeded the global thermal protect may activate which will attenuate the signal 40db when the temperature exceeds a preset point When the temperatu...

Page 11: ...d ISP will not be responsible for any damages incurred in shipping of any unit Any claim will need to be settled with the shipping company The warranty will be voided if the serial number has been tampered with in any way Should you have any questions for the repair department prior to returning the product please call 1 248 673 7790 NOTE This Product may be covered under one or more of the follow...