background image

 

 

           

REAR PANEL DESCRIPTION 

 

 

 

 

1.  LEFT HIGH PASS BALANCED OUTPUT- 

This XLR male connector provides a 

balanced high pass output from the left channel input.  The high pass frequency 
is set at 100 Hz with a 24 dB per octave roll off. 

                   

2.  RIGHT HIGH PASS BALANCED OUTPUT-

 This XLR male connector provides 

a  balanced  high  pass  output  from  the  right  channel  input.    The  high  pass 
frequency is set at 100 Hz with a 24 dB per octave roll off. 

                

3.  LEFT FULL RANGE BALANCED OUTPUT- 

This XLR male connector provides 

a

 

balanced full range output from the left channel input.  This connector may be 

used  to  daisy-chain  the  full  range  signal  to  additional  powered  sub  cabinets 
such as another SA118 or SA115. 

 

4.  RIGHT  FULL  RANGE  BALANCED  OUTPUT-- 

This  XLR  male  connector 

provides  a  balanced  full  range  output  from  the  right  channel  input.    This 
connector  may  be  used  to  daisy-chain  the  full  range  signal  to  additional 
powered sub cabinets such as another SA 118 or SA115. 

 

5.  INPUT PHASE SWITCH- 

This switch is used to change the polarity of the input 

signal going to the power amp of the subwoofer.  This will be dependent on the 
placement  of  the  Tripower  relative  to  the  subwoofer  or  if  another  type  of 
powered  cabinet  is  to  be  used.    The  (0)  setting  (switch  out)  will  make  the 
subwoofer phase coherent with any of the Tripower series.  This switch will not 
change the phase of any of the balanced outputs. 

 

6.  INPUT  SENSITIVITY- 

This  control  determines  the  overall  input  level  of  the 

signal  to  the power amp section of  the  subwoofer cabinet.   Adjusting  this level 
will not affect the level of the signal passing through to the full range or the high 
pass outputs. 

 

7.  LEFT BALANCED INPUT- 

This female XLR connector provides an input for the 

left channel signal source.  This will also feed the left channel signal to the left 
high pass and left full range balanced outputs. 

 

8.  RIGHT BALANCED INPUT-

  This  female  XLR  connector  provides  an  input  for 

the  right  channel  signal  source.    This  will  also  feed  the  right  channel  signal  to 
the left high pass and right full range balanced outputs. 

 

9.  EXTENTION SPEAKER OUTPUT- 

This Speakon connector provides an output 

for  a  passive  extension  speaker  such  as  the  SP115  or  SP118.    This  will  also 
increase  the  power  output  of  the  subwoofer  amplifier  from  600  watts  to  900 
watts.    If  another  cabinet  is  to  be  used  other  than  a  SP115  or  SP118  as  an 
extension cabinet, make sure the load of the extension speaker is not less than 
4 ohms. 

 

10. POWER SWITCH- 

This  switch  provides  power  to  the  subwoofer  amp  section.  

Make sure that the input sensitivity control is set to minimum upon power up 

 

11. POWER  INLET  MODULE- 

This  module  provides  a  connection  for  the  power 

cord and also houses the mains fuse.  

(See Fuse Replacement Section) 

Summary of Contents for SA115

Page 1: ...1 ...

Page 2: ... into this unit This active speaker system has an internal amplifier and an externally visible heatsink located on the back of the speaker for cooling of the internal amplifier Care should be taken to avoid placing this active speaker in a location where the external heatsink does not allow proper cooling of the internal amplifier Avoid placing this system close to other heat sources The external ...

Page 3: ...nnected to one of ISP Technologies passive satellite subwoofers SA115 or SA118 The amplifier receives its input signal from an internal fourth order crossover network specifically designed to provide optimized phase and frequency response for a composite system The internal amplifier is based on ISP Technologies patent pending D CAT Dynamic Current Amplifier Technology amplifier technology The D C...

Page 4: ...nt of the cabinet relative to floors and walls will affect the low frequency response Placing it closer to the floor and walls will reinforce the low frequency response Also make sure that adequate space at least 6 inches is left behind the cabinet for airflow over the internal amplifier heatsink A pole mount socket is provided on the top of the SA115 for mounting one of ISP Technologies Active Se...

Page 5: ...hase coherent with any of the Tripower series This switch will not change the phase of any of the balanced outputs 6 INPUT SENSITIVITY This control determines the overall input level of the signal to the power amp section of the subwoofer cabinet Adjusting this level will not affect the level of the signal passing through to the full range or the high pass outputs 7 LEFT BALANCED INPUT This female...

Page 6: ...he fuse cover module after it is pulled out NOTE A SMALL COMPARTMENT IS ALSO PROVIDED WITHIN THE FUSE COVER MODULE FOR STORING A SPARE FUSE 2 After replacing the fuse with another of identical specifications push the fuse cover module fully back into place ensuring that the fuse has snapped onto the fuse holder inside the power inlet module ...

Page 7: ...7 CONNECTION DIAGRAM ...

Page 8: ...igured to AES standards Audio Engineering Society These connections are connected in a loop through configuration from the inputs to the full range outputs and will accept a balanced line level input The standard phase configuration is that pin 2 is pin 3 is and pin 1 is shielded ground on the XLR ...

Page 9: ...ansformer has internal thermal fuse self resetting Transducer Low Frequency Transducer Diameter 15 381mm Voice Coil Diameter 3 76 2mm Power Handling 400 watts RMS D CAT Technology Power Amplifier Low Frequency Amplifier Power Output Stand Alone 600 watts RMS Power Output with SP115 SP118 900 watts RMS THD 0 06 typical Line Input Power Voltage 117VAC 60 Hz Current 6 9 amps Power 800 watts Physical ...

Page 10: ...rnally mounted on the rear of the cabinet Airflow is forced through the fins via the air pressure from the speaker It is recommended that the fins have at least 6 inches of clearance from any obstruction to allow proper ventilation to occur In addition the amplifiers are thermally protected internally via a thermal switch which will attenuate the signal 40db when the temperature exceeds a certain ...

Page 11: ...l not be responsible for any damages incurred in shipping of any unit Any claim will need to be settled with the shipping company The warranty will be voided if the serial number has been tampered with in any way Should you have any questions for the repair department prior to returning the product please call 1 248 673 7790 NOTE This Product may be covered under one or more of the following paten...

Reviews: