1 Introduction

1.1 General

Isotherm refrigerators are specially designed to operate in tough 
marine environments. They are fi tted with a fully hermetic, 
leak-free compressor, they offer the lowest possible power 
consumption and noise level. All models are simple to install. 
They can withstand an angle of heel up to 30°, for a short time. 
To ensure that your Isotherm fridge operates as effi ciently as 
possible, please follow these general guidelines:
• Unnecessary opening of the fridge door will increase power  
  consumption.
• Good ventilation of the compressor and condenser unit will 
   reduce power consumption.
• The electrical system should be in good condition. Inspect  
   batteries and charging levels regularly. Always use a separate 
   starter battery for the engine. Follow carefully the guidelines 
   regarding electrical able areas and fuse placements.
• Keep the inside of the fridge and freezer clean and dry.  
  Remove any water from condensation that may have collected  
  in the plastic baskets.
• Keep the door slightly open to air the refrigerator and freezer  
  when leaving the boat for any length of time. (Fig. 1 and 2)

1.2 Safety and precautions

For your own and others safety, read this fi rst.

I.3 Environmental markings

The symbol          on the product, or on the documents 
accompanying the product, indicates that this product may 
not be treated as household waste. Instead it shall be handed 
over to the applicable collection point for recycling of electrical 
and electronic equipment. Disposal must be carried out in 
accordance with local environmental regulations for waste 
disposal.
For more detailed information about treatment, recovery and 
recycling of this product, please contact your local city offi ce, 
your household waste disposal service or the shop where you 
purchased the product.
     

     

 

Danger! 

Only connect the device to a 110 - 230 Volt power 

outlet installed according to regulations, being accordingly 
fused.
When connected to mains power, ensure that the power 
supply is equipped with an earth safety automatic switch, a 
”ground fault circuit interrupter”.

 

Danger! 

Never touch bare electrical wiring connected to 

the AC power supply.

 

Do not use the device if the connector cables show visible 
damage. 
Never connect battery charger direct to the refrigeration 
system. 
A battery charger 

must

 be connected to the battery, never 

direct to the refrigeration system. 

Danger! 

In addition to acid, a newly-charged battery 

contains explosive gas. 
Never cover the ventilation openings for the compressor 
unit.
Refrigerant may never be let out in the air.

2 Installation instructions

Many boats have a space which is intended for a fridge. The 
Isotherm Cruise fridge has been designed to suit the general 
dimensions normally used for this purpose.
The compressor should normally stand upright in the boat, but 
will operate at an angle of heel up to 30° and for short periods 
even more. The compressor on CR200 is attached by its rear 
side.  
The refrigerator/freezer unit has a three side mounting fl ange to 
fasten the unit in place. It must also be standing on its feet.  
See installation dimensions on fi g. 10.
Avoid mounting close to a heat source, like gas ovens and 
heaters. Also avoid a position allowing direct sunshine on the 
refrigeration/freezer unit.
The mounting position should be dry and protected from 
splashing water.

2.1 Ventilation

It is very important that the compressor/condenser unit is 
well ventilated and that cold air can enter at the bottom, 
pass behind the fridge and warm air can leave at the top in 
the area where it is mounted. The natural fl ow of air from 
below and upwards behind the fridge can be increased by 
arranging ventilation openings at the rear.

Make sure there is a free area of 23 - 28 sq.in. below and behind 
the refrigerator/freezer to allow ventilation air to pass behind 
from below. See fi g 5.

2.2 Electrical connections/wiring for power supply

CR200  is available in two versions, one is equipped with a 
Danfoss 12-24 VDC electronic unit and the other is equipped 
with a AC-DC electronic unit. It is important that following points 
are considered:

DC (12 or 24 volt)

The electronic unit must always be connected direct to the 
battery poles. Connect the positive/plus to + and the negative/
minus to - on the battery. Without proper positive/negative 
connections, the electronic unit will not work - it is protected 
against reverse battery connection. 
For protection of the installation, a fuse must be mounted in the 
positive cable as close to the battery as possible. 
A 15A fuse for a 12V power supply and a 7.5A fuse for a 24 volt 
circuit are recommended. If a breaker box connection is used, it 
should be rated to a minimum of 20A.
Avoid extra junctions in the power supply system to prevent 
voltage drop from affecting the battery protection setting.
The light is connected to battery power on the electronic unit and 
the bulb must be selected 12 or 24 volt. Both types are included 
in the delivery.  
See wiring diagram fi g. 8

AC (100-240 volt)

The live and neutral wires must be connected to the terminals 
marked 

L

 and 

N

 on the electronic unit. Nominal voltages from 

100 to 240 VAC 50/60 Hz. Upper safety cut out limit is 270 VAC 
and lower limit is 80 VAC.Earth connection is to be placed on the 
compressor foot near the electronic unit. There is a hole drilled 
in the foot for this purpose, use a 5/32” screw and nut and a ring 
cable shoe on the wire.
Connection of mains power plug must fulfi l valid electrical safety 
regulations and properly fused with 4A. Wire gauge, AWG18.