Isotherm 3160BB1C Instruction Manual Download Page 13

 

 

Manuale d’uso – User’s Manual 
 
 

 

 

CG 23072012 Ver 1.2   Pag. 

13

 

Installation 

 

Almost all boats have a specific space for the 
installation of the refrigerator. Isotherm fridge / 
freezer is designed to meet the normal size of 
installation. 
The compressor must stay in upright position but 
will work even with a 30 degrees swing and more 
for short periods. 
The minimum requirements for installation on 
board are: 
• 2 cm light above the unit (between the fridge 
and line of furniture); 
• Laterally, the walls of the refrigerator can be put 
in contact with the furniture, except the spaces of 
vents where 90 mm openings shall be made (see 
figures below) 

 

Make nr. 2 holes opposite 90mm with safety grid 
in correspondence with the air vents and make 
sure the environment beyond the holes is open 
and well ventilated

 

 
 

 

 
If the environment in correspondence with the 
holes is not free and well ventilated you should 
use a flexible hose to funnel air (optional) both on 
device’s entry and exit, from and to open 
environments with the possibility of air circulation. 
In these environments, any apparatus/equipment 

which can increase air temperature must be 
present. 
The air intake is on the left side of the apparatus 
and it is recommended that air comes from an air 
conditioned environment. See fig. below.

 

 

Frontal View 

 

 

 
 

Recommended Installation 
 

In order to maximize performance and efficiency 
of the product (optimal functioning and reduced 
power consumption), we suggest adding at the 
minimum requirement of 2cm light at the top, 
further 2cm light on each side. 

 
 
 
Fixing 
 

For mounting the unit, use self-tapping screws 
with diameter 3.2 mm, 16mm length. The device 
should be fixed by a mounting flange bearing 
holes (see figure below). 
Make sure that the material, where the unit is 
fixed, is solid and robust. After mounting check 
that the device is stable and immobile. 

 

 

Summary of Contents for 3160BB1C

Page 1: ...Manuale di Istruzioni Instruction manual DR 160 INOX COMBO DOUBLE DRAWER INTEGRATED ICE MAKER Ver 1 1...

Page 2: ...nzionamento pi efficiente possibile del refrigeratore Isotherm attenersi alle seguenti istruzioni Evitare di aprire i cassetti dell apparecchio se non necessario Assicurare una buona ventilazione del...

Page 3: ...ispondenza dei fori non libero e ben areato si consiglia di utilizzare un tubo flessibile di canalizzazione aria opzionale sia in ingresso che in uscita dall apparecchio da e verso ambienti aperti con...

Page 4: ...stro adesivo alla parete dell apparecchio L apparecchio pu essere direttamente alla rete idrica di bordo La pressione di quest ultima deve essere contenuta tra 1bar e 10bar Ventilazione E estremamente...

Page 5: ...parte Freezer sinistra si potr impostare la temperatura del cassetto congelatore Alla prima pressione verr indicata la temperatura precedentemente impostata mentre alle successive pressione la tempera...

Page 6: ...periodo di non utilizzazione dell apparecchio per consentire un adeguata ventilazione all interno dei vani assicurarsi che l apparecchio sia spento per evitare sprechi di corrente causati dall accens...

Page 7: ...Manuale d uso User s Manual CG 23072012 Ver 1 2 Pag 7 Schema Elettrico...

Page 8: ...Manuale d uso User s Manual CG 23072012 Ver 1 2 Pag 8 Disegno Tecnico...

Page 9: ...afughe eventuali perdite di gas refrigerante Riparare la possibile perdita Eseguire il vuoto del sistema e ricaricarlo con l apposito gas refrigerante R134a Il compressore funziona per lunghi periodi...

Page 10: ...ure indicate devono essere scrupolosamente osservate La classe climatica dell apparecchio riportata sulla targhetta dati CLASSE CLIMATICA Predisposto per temperatura ambiente SN 10 fino a 32 C N 16 fi...

Page 11: ...re nell apparecchio materiali esplosivi o bombolette spray a base di sostanze infiammabili come per esempio butano propano pentano ecc A contatto con le parti elettriche le eventuali perdite di gas po...

Page 12: ...nks to the digital control panel located on the top drawer To ensure the most efficient operation of the Isotherm refrigerator follow these instructions Avoid opening the drawers of the equipment if n...

Page 13: ...correspondence with the holes is not free and well ventilated you should use a flexible hose to funnel air optional both on device s entry and exit from and to open environments with the possibility...

Page 14: ...fixed with adhesive tape to the wall of the unit The device can be connected directly to the on board water connection Pressure must be included between 1bar and 10bar Ventilation It s extremely impor...

Page 15: ...ft you can set the temperature of the freezer drawer The first pressure will show the previously set temperature and the subsequent pressure will vary the temperature of 1 C each time both positive an...

Page 16: ...g the period of non use of the apparatus to allow adequate ventilation inside the compartments make sure the device is switched off to avoid waste of power caused by turning on LED lighting Defrost Cy...

Page 17: ...Manuale d uso User s Manual CG 23072012 Ver 1 2 Pag 17 Wiring Diagram...

Page 18: ...Manuale d uso User s Manual CG 23072012 Ver 1 2 Pag 18 Technical Drawing...

Page 19: ...with the leak detector possible leaks of refrigerant gas Repair the possible leak Run the vacuum of the system and recharge it with a special refrigerant gas R134a The compressor runs for long period...

Page 20: ...indicated must be carefully observed The climate classification of the unit is written on the data plate CLIMATE CLASS Preset to room ambient temperature SN From 10 to 32 C N From 16 to 32 C ST From...

Page 21: ...explosives nor aerosols based on flammable substances such as butane propane pentane etc in contact with electrical parts because possible leaks may catch fire Spray cans containing such substances c...

Page 22: ...rifiuto domestico ma deve essere consegnato presso l idoneo punto di raccolta per il riciclaggio di apparecchiature elettriche ed elettroniche Disfarsene seguendo le normative locali per lo smaltimen...

Page 23: ...nna produkt var god kontakta de lokala myndigheterna ortens sophanteringstj nst eller butiken d r produkten inhandlades E Este aparato lleva el marcado CE en conformidad con la Directiva 2002 96 EC de...

Page 24: ...Agata Feltria PU ITALY Tel 39 0541 848030 Fax 39 0541 848563 E MAIL info indelwebastomarine com WEB www indelwebastomarine com 3400 Gateway Drive Unit 107 Pompano Beach FL 33069 Phone 954 984 8448 Fax...

Reviews: