background image

 

 

 

 

 

 

 

–– 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Length to Panel 

Length 

AWG 

200’ (60 m) 

22 

300’ 

20 

500’ 

18 

Common Cable Connections 

Red 

Power In 

Black 

Ground 

Shield 

Shield Ground 

Brown* 

Tamper Out 

Green 

Wiegand Data 0 / RS 485A 

White 

Wiegand Data 1 / RS 485B 

Yellow* 

Beeper Control 

Blue* 

Green LED Control 

Orange* 

Red LED Control 

Current @ 12 V and 25 C 

Avg. mA 

Max. mA 

110 

160 

Current for ET25 @ 12 V and 25 C 

Avg. mA 

Max. mA 

140 

190 

Attach the Reader to the Wall plate  

Align the reader so that the tabs of the base plate slide into 
the slots on the wall plate and slide the reader into position.  

 

 

Install Metal Wall Plate to Single Gang Box 

Connect the wall plate to the single gang box using the provided #6 screws. Alternatively you can use the provided #4 screws in 
the four outer holes for other installation requirements. Drywall installations will require molly bolts.   

 

Wire the Cable to the Control Panel 

 

 
 

 

1

 

*these wires are only used in 
Wiegand readers.   

Alternative for 
situations 
outside of a 
single gang box 
installation.  

Standard Single 
Gang Box 
Installation 

 
Questions? Scan our QR code or visit      

www.isonas.com/support/installFAQ

 

 

PURE IP™ WIEGAND READER 
QUICK INSTALLATION INSTRUCTIONS

 

MODELS: R-1-MCT-W, R-1-MCT-WK

 

 

*Patent Pending 

This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  (1) this device may not cause harmful interference, and (2) this 

device must accept any interference received, including interference that may cause undesired operation. 

Changes or modifications not expressly approved by WaveLynx could void 

the user's authority to operate the equipment.

 

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause 

interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

 Le présent appareil est conforme aux CNR 

d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, 
et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

 

Install the Reader Screw 

Install the #4-40 screw or pin-in-torx at the bottom of the 
reader.  

Test the Reader 

Power the reader, the red light-bar will light, followed by a beep. 
Present a valid credential to the reader and the light-bar will turn 
green. 

 

Screw or 
pin-in-
torx 

Tools Required: 

Items Included: 

1”(25mm), 1/8” drill bits 

Reader, Backplate & Wall  Plate 

Phillips Screwdriver 

(2) #6 Screws 

T8 Security Torx Bit 

(1) #4-40, (1) pin-in-to 

 

(4) #4 Screws 

 

Reviews: