background image

8- 

  MENU 

  To select the programming functions 

  DOWN 

  To go backward in the selected functions 

  UP 

  To go forward in the selected functions 

  ENTER 

  To confirm the selected functions 

 

Remote controller input 

By connecting to the 1/4” microphone jack to control the unit for Stand by, Function, and 
Mode function. 

Sensitivity 

To adjust the sound-receiving sensitivity . 

Microphone 

To receive audio signal for sound activation . 

DMX input/output 

For DMX512 link, use 3-pin XLR plug cable to link the unit together. 

9- 

 4.2. Main Function  

To select any of the pre-set functions, press the 

MENU

 button up to when the required one 

is shown on the display. Select the function by 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to change the mode. Once the required mode has been selected, 

press the 

ENTER

 button to setup or it will automatically return to the main functions without 

any change after idling 8 seconds. To go back to the functions without any change press the

 

MENU

 button. The main functions are shown below: 

MENU

Self-Test

Reset

Fixture Hours

Display Inversion

Display Normal

Tilt Inversion

Tilt Normal

Pan Inversion

Pan Normal

Slave mode " 2 Light Show "

Slave Mode " Normal "

DMX512 Address Setting

Blackout Mode " No Blackout "

Blackout Mode " Yes Blackout "

LED on
LED off

Setting 16 Channel
Setting 8 Channel

Show mode 2

Show mode 1

Show mode 3
Show mode 4

Ambient temperature of lamp

Lamp off

Lamp on

 

 

DMX512 Address Setting

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address.   

Once the address has been selected, press the 

ENTER

 button to setup or automatically 

return to the main functions without any change after 8 seconds. To go back to the functions   

without any change press the

 MENU

 button again. 

Summary of Contents for IMOVE 250W

Page 1: ...n 2 Technical Specification 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjustment 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2...

Page 2: ...of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the near...

Page 3: ...and beam shape effect Movement Pan 540 in 2 8 second Tilt 270 in 1 6 second DMX Channels Standard DMX512 signal addressing and can be controlled by any universal DMX controller 16 Channels Channel 1 P...

Page 4: ...generates UV radiation Never operate the lamp without appropriate shielding 4 When burning the lamp operates at high pressure and there is a slight risk of arc tube rupture The risk increases with ag...

Page 5: ...setup or it will automatically return to the main functions without any change after idling 8 seconds To go back to the functions without any change press the MENU button The main functions are shown...

Page 6: ...nds To go back to the functions without any change press the MENU button again 11 Blackout Mode Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will...

Page 7: ...play Pressing ENTER button and all channels of the unit will return to their standard position To go back to the functions press the MENU button again DMX RESET 13 Set DMX value of channel 8 and chann...

Page 8: ...to the 1 4 microphone jack of the first unit you will find that the remote control on the first unit will control all the other units for Stand by Function and Mode Stand by Blackout the unit Function...

Page 9: ...you use IL 0824 controller DMX address can be set remotely by IL 0824 controller No need to calculate the DMX channels of each fixture in the chain Please refer to the following diagram to address you...

Page 10: ...put of the unit to the input of the next unit The cable cannot be branched or split to a Y cable DMX512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors...

Page 11: ...ress in the unit Set the proper address D No response to the sound 1 Check the unit that is not receiving DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the chan...

Page 12: ...Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days y EC De...