background image

 

15- 

  5.1. Master/Slave Built-In Preprogrammed Function   

Once you control the unit by Built-In program, be sure the unit is setting on 

 mode 

via menu.   

By linking the units in master/slave connection, the first unit will control the other units to 

give an automatic, sound activated, synchronized light show. This function is good when you 

want an instant show. You have to select show (show 1, 2, 3, 4) modes for the first unit 

(master). Its DMX input jack will have nothing plugged into it, and Its master LED will be 

constantly on and sound LED will flash to the music. The other units will have to set in slave 

mode 

 and select 

 (normal) or 

 (2 light show) mode, Their DMX 

cables plugged into the DMX input jacks (daisy chain) and the slave LED lights will 

constantly on.

 

2-light show

 

In 

 (slave mode),

 

means the unit works normally and 

 

means 

2-light show. In order to create a great light show, you can set 

 

on the second unit 

to get contrast movement to each other, even if you have two units only. 

 

 

5.2. Easy Controller 

   

The easy remote control is used only in master/slave mode. By 

connecting to the 1/4” microphone jack of the first unit, you will find 

that the remote control on the first unit will control all the other units for 

Stand by, Function and Mode. 

Stand by  Blackout the unit 

Function 

Strobe 
1. Color sync. strobe 
2. Sync. strobe 
3. Two-light strobe

 

X/Y moving show pattern 
selection 
( Show 1 ~ Show 4 ) 
Please refer to 4.2. Main 
Functions- Show mode 
 

Gobo/Color selection   
1.Hold on for gobo 

selection 

2.Press for color change

X/Y moving setting 
1.Macro(sound active) 
2.Fade (sound invalid) 

 

Mode 

Sound 1 
(LED off ) 

Sound 2 
(LED slow blinking) 

Slow/Sound 3 
(LED on) 

Position/ Latch 
(LED fast blinking) 

 

  5.3. DMX Controller   

If you use a universal DMX controller to control the units, you have to set DMX address from 

1 to 512 channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. 

 

12- 

   

Display normal mode for the fixture putting on the floor. 

   

Display inversion mode for the fixture fixing under ceiling. 

   

Focus Adjust

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button, the unit will focus on tilt 90°, and then the unit will focus on tilt 0°, pan 0°, pan 90°, 

pan 180°, pan 270° in every pressing 

ENTER

 button. To go back to the functions press the

 

MENU

 button again.

 

   

Self-Test 

Press the 

MENU

 button up to when the 

 

is blinking on the display. Pressing 

ENTER

 

button and the unit will run self-test by built-in program. To go back to the functions press the

 

MENU

 button again. 

   

Ambient temperature of lamp 

Press the 

MENU

 button up to when the 

 

is blinking on the display. Pressing 

ENTER

 button and the ambient temperature of lamp will show on the display. To go back to 

the functions press the

 MENU

 button again. 

   

Fixture Hours 

Press the 

MENU

 button up to when the 

 

is blinking on the display. Pressing 

ENTER

 

button and the display will show the number of working hours of the unit. To go back to the 

functions press the

 MENU

 button again. 

 

 Lamp ON/OFF

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (Lamp on) 

or 

  (Lamp off) mode. Once the mode has been selected, press the 

ENTER

 button 

to setup. Idling 8 seconds automatically exit menu mode. Back to the functions without any 

change press 

MENU

 button. 

   

Reset 

Press the 

MENU

 button up to when the 

 

is blinking on the display. Pressing 

ENTER

 

button and all channels of the unit will return to their standard position. It will cost about 20 

Summary of Contents for IM-250SW

Page 1: ...Innovation Quality Performance IM 250SW User Guide Please read these instructions carefully before use...

Page 2: ...1...

Page 3: ...et The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjustment 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 DMX Controller 5 4 DMX 5...

Page 4: ...rature is higher than this z Unit surface temperature may reach up to 85 Don t touch the housing bare hand during its operation and allow about 15 minutes to cool down before replacing bulb or serving...

Page 5: ...not expose the unit to rain or moisture z Never touch bulb with bare fingers as it is very hot after using z Hot lamp explosion hazard Do not open the unit within five minutes after switching off z Do...

Page 6: ...plus open 5 metal gobos 2 glass gobos are included Gobo wheel rotates with variable speed giving shaking effect Effect Wheel Prism Rotating Prism Movement Pan 540 in 2 8 second Tilt 270 in 1 6 second...

Page 7: ...2 6 Luminous intensity Dimension 428 x 369 x 466 mm L x W x H Weight 23 kg 2 1 Inserting Exchanging rotating gobos DANGER Install the gobos with the device switched off only Unplug from mains before c...

Page 8: ...sk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of...

Page 9: ...s in the unit Set the proper address D No response to the sound 1 Make sure the unit is not receiving DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels...

Page 10: ...512 channels 1 If you use a controller with 5 pins DMX connector you need to use a 5 to 3 pin adapter 2 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor...

Page 11: ...tion i e in front of the stage Pan movement angle left to right to left 160 Tilt movement angle 90 60 above horizon 30 below horizon Show 4 mode Fixture is fixed under ceiling The spot is mainly proje...

Page 12: ...up to when the is showing on the display Pressing ENTER button and will blink on the display use DOWN and UP button to adjust the value from 125 to 255 press ENTER button to store and will blink on t...

Page 13: ...X controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is shown on the display Pressing ENTER...

Page 14: ...e the position has been selected press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again To go back to the main functions without...

Reviews: