22
QUICK START MENU
The user has immediate access to the Quick Start menu when the converter is powered up
by pressing the Enter key. If access to the quick start menu does not occur, then it has
been disabled through function 8.6
The set up functions (batching, regulation, flow and SMART measure) regulate
automatically the values of filters for the operation set modifying optimally the parameters
related to the function chosen.
To enable one of
four types operation press the key Enter while the function is
highlighted, to confirm the changes press long the Enter key.
Filters settings for different S.rate (sensor menu, not user modifiable):
Batching
Regulation
Flow measure
SMART measure
MFSLN
MFFLN
MFSLN
MFFLN
MFSLN
MFFLN
MFSLN
MFFLN
10Hz
0
0
10
0
20
0
100
10
20Hz
0
0
5
0
10
0
50
5
50Hz
0
0
2
0
4
0
20
2
80Hz
0
0
1.3
0
2.5
0
12.5
1.25
150Hz
0
0
0.7
0
1.3
0
6.7
0.67
See the functions description section for more details over the filters.
See programming functions section
Automatic parameters optimization (see below)
Access to all functions