Page 1: ...IFX P200 Hand held Ultrasonic Flowmeter Hand held_Flow_Meter_IFX P200_EN_2017_July_Rev 01...

Page 2: ...mp on sensor mounting configurations and distance 12 3 6 Flowmeter installation 14 3 6 1 Outline dimensions 14 3 7 Clamp on sensor mounting 15 3 7 1 Sensor pipe mounting configurations 15 3 7 2 Acoust...

Page 3: ...31 5 3 1 Main PV 31 5 4 Output settings 31 5 4 1 Serial interface RS 232 31 5 5 IS0FLUX download software 31 5 6 Wall thickness measurement WTM 31 5 6 1 Wall Thickness Gauge WTG Wizard 31 5 7 Scope f...

Page 4: ...azard and have taken the required precautions Attention This symbol indicates important instructions which should be respected in order to avoid damaging or destroying the equipment Follow the precaut...

Page 5: ...or future reference Observe all warnings notes and instructions as marked on the pack aging on the equipment and detailed in the operating instructions Do not use the instrument under wet conditions w...

Page 6: ...ansducer These signals are emitted alternately in the direction of flow and against it Because the medium is flowing the transit time of the sound signals propagating in the direction of flow is short...

Page 7: ...IFX P200 User Manual 7 Hand held_Flow_Meter_IFX P200_EN_2017_July_Rev 01 2 1 How to order...

Page 8: ...age during transport and any problems reported immediately The vendor accepts no responsibility for damage or injury caused during the unpacking of the instrumentation supplied Excess packing material...

Page 9: ...material lining wall thickness and general condition of the pipe the medium flowing in the pipe and the presence of gas bubbles and solid particles in the medium Check that the temperature at the sel...

Page 10: ...bottom of the pipe and the gas pockets developing at the top will not influence the propagation of the signal Correct Incorrect For a free inlet or outlet pipe section Select the measuring point at a...

Page 11: ...L 5 D Disturbance source 2 x 90 elbows in one plane Inlet Outlet L 25 D L 5 D Disturbance source 2 x 90 elbows in different planes Inlet Outlet L 40 D L 5 D Disturbance source T section Inlet Outlet...

Page 12: ...es The Reflection Mode is the most convenient mounting method as the transducer separation distance can be measured easily and the sensors can be accu rately aligned This method should be used wheneve...

Page 13: ...d thickness medium process temperature the sensor type and the selected number of signal passes A negative separation distance A 0 can occur for mounting configurations on small pipes where diagonal m...

Page 14: ...Flowmeter installation 3 6 1 Outline dimensions The IFX P 200 is a hand held battery operated device with the following out line dimensions K4 type transducer Flowmeter outline dimensions K1 type tran...

Page 15: ...d the clamp on sensors are either mounted on the same side of the pipe Reflection Mode or on opposite sides of the pipe Diagonal Mode See Section 2 5 3 7 1 Sensor pipe mounting configurations 3 7 2 Ac...

Page 16: ...ing the screw knob Apply some acoustic coupling component to the contact surface of the transducer Place the transducer on the side of the pipe or alternatively up to 45 degrees from the horizontal pl...

Page 17: ...IFX P200 User Manual 17 Hand held_Flow_Meter_IFX P200_EN_2017_July_Rev 01 Illustration 6 Sensor mounting with fixtures and chains retaining clip...

Page 18: ...ckel Metal Hydride NiMH AA size re chargeable batteries are installed attempting to recharge other bat tery types is dangerous and may cause damage Connect the battery charger to the charging socket o...

Page 19: ...ction Character entry 1 1 short key stroke 2 short key strokes 3 short key strokes _ 4 short key strokes Show NEXT available item Character entry A B C 2 QON Start totalizer function Character entry D...

Page 20: ...X Y Z 9 DIRECT access to trend plot Move menu list selection item UP Character backspace clear Character entry decimal point Switch LCD backlight on off Character entry 0 Space character Move menu li...

Page 21: ...g Battery charging On LCD backlight switched on Off LCD backlight switched off On Icon not used Off On Without strike through Speaker on Off with strike through Speaker off On Poor sensor coupling low...

Page 22: ...keys to select Setup Wizard Con firm by pressing ENTER If sensors are recognised the serial number will be shown If not recognised or not connected they may be selected from a list Select units of mea...

Page 23: ...ckness Entering a new value here will recalculate the Outside Di ameter Select fluid using cursor keys Confirm by pressing ENTER Enter process temperature using alphanumeri cal keys and confirm by pre...

Page 24: ...bers shown are for indication only Success 4 5 Measurements 4 5 1 Main process value PV display Measurement is started using the Quick Setup Wizard Once all the param eters are programmed any subseque...

Page 25: ...ine display format Display screen Operation The three line display screen is config urable to show flow totalizers and diag nostic functions Change to diagnostic displays by pressing DISP and to total...

Page 26: ...essing Q resets the total accumulated flow in the positive flow direction Pressing Q resets the total accumulated flow in the negative flow direction The totalisers can be stopped by pressing QOFF Pre...

Page 27: ...input or calculated value Math Calculated value see below Pipe material Select from list Stainless steel Carbon steel Ductile cast iron Grey cast iron Copper Lead PVC PP PE ABS Glass Cement User pipe...

Page 28: ...sors Crystal offset SP5 only for special unrecognised sensors Spacing offset SP6 only for special unrecognised sensors Zero flow offset SP7 only for special unrecognised sensors Upstream off set SP8 o...

Page 29: ...from list ENTER to select 0 to remove Availible items as in list for display output Low Memory Warning output The amount of memory remain ing at which the flowmeter begins to give an audi ble warning...

Page 30: ...erature time date clock battery meter charger test routine Ultrasonics Tests ultrasonic board and sensors Settings Date Example 03 10 07 Time Example 09 27 00 Date Format Select from list dd mm yy mm...

Page 31: ...sure pipe wall thickness are available The IFX P200 will recognise a connected probe when entering the Setup or WTG Wizards the measurement mode or the Scope function Use the Setup Wiz ard or Installa...

Page 32: ...Scope function ISOFLUX flowmeters have an additional scope function which shows a rep resentation of the pulse received by the sensors In addition to displaying the received pulse this screen lists t...

Page 33: ...that Isoil can only service this device if it is accompanied by a Return Merchandise Authorization RMA confirming that the de vice is safe to handle If the device has been operated with toxic caustic...

Page 34: ...rdware SPI bus failure Power on off otherwise call customer support I2C ERR Hardware I2C bus failure Power on off otherwise call customer support MATH ERR Software Internal calculation error Call cust...

Page 35: ...ifficulties are encountered downloading the logger data Check that the flowmeter is switched on and not in measurement mode Check that the same number COM port is allocated in the Device Manager or eq...

Page 36: ...59 Brass Naval 2 120 6 923 Gold hard drawn 1 200 3 937 Inconel 3 020 9 909 Iron electrolytic 3 240 10 630 Iron Armco 3 240 10 630 Ductile Iron 3 000 9 843 Cast Iron 2 500 8 203 Monel 2 720 8 924 Nicke...

Page 37: ...9 34 851 n Butyl bromide 46 C4H9Br 1 276 20 C 1 019 20 C 3 343 2 68 F 0 49 15 C 5 272 59 C n Butyl chloride 22 46 C4H9Cl 0 887 1 140 3 740 2 4 57 0 529 15 C 5 692 59 F Carbon tetrachloride CCl4 1 595...

Page 38: ...222 20 C 4 009 2 68 F 2 Propanol C3H8O 0 785 20 C 1 170 20 C 3 838 6 68 F 2 718 29 245 Propene C3H6 0 563 13 C 963 13 C 3159 4 9 F 6 32 n Propyl alcohol C3H8O 0 78 20 C 1 222 20 C 4 009 2 68 F 2 549...

Page 39: ...996 1 498 4 914 7 2 4 1 00 10 76 Water heavy D2O 1 400 4 593 Water sea 1 025 1531 5023 2 4 1 00 10 76 Temperature Sound Speed in Water C F m s ft s 0 32 0 1402 4600 1 33 8 1407 4616 2 35 6 1412 4633...

Page 40: ...5079 57 134 6 1548 5079 58 136 4 1548 5079 59 138 2 1550 5086 60 140 0 1550 5086 61 141 8 1551 5089 62 143 6 1552 5092 63 145 4 1552 5092 64 147 2 1553 5092 65 149 0 1553 5095 66 150 8 1553 5095 67 15...

Page 41: ...6 116 240 0 1524 5000 121 250 0 1516 5007 127 260 0 1507 4944 132 270 0 1497 4912 138 280 0 1487 4879 143 290 0 1476 4843 149 300 0 1465 4807 154 310 0 1453 4767 160 320 0 1440 4725 166 330 0 1426 467...

Page 42: ...tteries Display LCD graphic display 128 x 64 dots backlit Dimensions H 228 x W 72 117 x D 47 mm Weight Approx 650 g Power consumption 10 W Measurement rate 1Hz standard higher rates on application Ope...

Page 43: ...2 266 F Type K4E 30 250 C 22 482 F Degree of protection IP 66 acc EN 60529 IP 67 and IP 68 optional Isoflux Software Functionality Downloading of measured values parameter sets graphical presentation...

Page 44: ...for continuous unattended use Apparecchiature elettriche per solo uso continuo incustodito BS EN 61000 4 2 2009 Electrostatic discharge Scariche elettrostatiche BS EN 61000 4 3 2006 RF field Campo RF...