7.1 Care of the Device
The care of the MaxiFil is limited in general to cleaning all surfaces from dust and
deposits as well as checking the filter inserts.
WARNING
Skin contact with cutting fumes, etc. can cause skin irritation in
sensitive individuals!
Severe damage to health of respiratory organs and the respiratory
tract!
To avoid contact and the inhalation of dusts, use protective
clothing, gloves and a fan-breathing protection system e.g.
KEMPER autoflowXP or a Class FFP2 breathing filter mask
according to EN 149.
The release of dangerous dusts must be avoided during cleaning
So that persons not assigned with the task are not harmed.
INFORMATION
Do not clean the MaxiFil with compressed air! This may result in dust
and/or dirt particles getting into the ambient air.
Proper care helps to maintain the MaxiFil in a continuous functional state.
Ɣ
Clean the MaxiFil thoroughly once a month.
Ɣ
When cleaning the suction arm, also eliminate any accumulated dust or other
deposits on the protective grating (sold separately) or in the interior of the exhaust
hood.
Ɣ
The exterior areas of the MaxiFil can be cleaned with a suitable industrial vacuum
cleaner of dust class H or alternatively wiped with a wet cloth.
Ɣ
Check the hose on the extraction arm for damage e.g. burns holes from sparks or
chafing.
Information
Major defects and leaks lead to a reduction of the extraction
efficiency of the suction hood. Replace the hose with a new one in
time.