background image

AC V / DC V

 

Resistance / Diode

 

 

Input Impedance

 

4K for input voltage up to 30V.  

Impedance increases with input voltage  
to approximate 375K

 

at 600V. 

 

 Warning  

Do not apply more than 1000VDC / 600 
VAC between Tester terminal and earth 
ground.

 

AC A

 

Data Hold

 

I

100A

0A

Data Hold is not available when  
“OL K

is displayed with no input  

signals.

 

Data Hold Beep Guard 

 

The internal sounder will beep continu-
ously with LCD display flashing in two 
situations in the Data Hold mode: 
1. The Meter measures a signal different  
    from the LCD reading. 
2. The measured signal is the same as  
    the LCD reading and is larger 50  
    counts than the LCD reading. 

 

Auto Hold  

( ACA only )

 

I

100A

3.0A

2

Beep three times

1

2

0A

3 After 5Sec

1

4

 CAT.

.600V 

with respect to  
earth for the jaw. 

 
Barrier for 
Hand Guard 

 

 Do not hold  

the meter across  
the Barrier 

  Caution  

 

When connecting the test leads to the  

circuit or device, connect the black lead 
before the red lead ; when removing the 
test leads, remove the red lead before 
the black lead.

 

 Caution 

If the meter is used in the vicinity of equip-
ment which generates electromagnetic 
interference, the display may  
become unstable or the measurements 
show may be subject to large errors.

 

Summary of Contents for ICM A9

Page 1: ... Enable Disable Self Testing Aid Continuity Instruction Manual ICM A9 Electrical Clamp Multimeter EN ICMA9 Safety Information To ensure safe operation and service of this Clamp multimeter read these instructions completely before use and comply with them fully when using it Failure to observe these warnings can result in severe injury or death Avoid working alone so assistance can be rendered Do n...

Page 2: ...gnal different from the LCD reading 2 The measured signal is the same as the LCD reading and is larger 50 counts than the LCD reading Auto Hold ACA only I 100A 3 0A 2 Beep three times 1 2 0A 3 After 5Sec 1 4 CAT Ⅲ 600V with respect to earth for the jaw Barrier for Hand Guard Do not hold the meter across the Barrier Caution When connecting the test leads to the circuit or device connect the black l...

Page 3: ...f resistance 2 times sec of ACA Overrange display OL is displayed for Ω function shows the real value for A and V function Automatic power off time Approximately 20 minutes after power on without operations Low battery indicator is displayed Replace the battery when the indicator appears in the display Power requirement 9V battery Battery type and life ALKALINE PP3 9V 250 hours Ⅰ The circuits not ...

Page 4: ...ose are limited to the above The manufacturer shall not be liable for loss of use of the instrument or other incidental or conse quential damages expenses or economic loss or for any claim or claims for such damage expense or economic loss Some states or countries laws vary so the above limitations or exclusions may not apply to you For full terms and conditions refer to the current RS Catalogue A...

Reviews: