Instructions Manual of Communication Interfaces MI485 / MI486 / MI488

 

 

After connection to power supply voltage, the Power LED indicates the presence of power supply, while the diodes on the ethernet 
terminal indicate the presence of the ethernet network. If network is active, one LED is lit or is blinking (the left LED indicates 10 
Mb/connection /activity, and the right LED indicates 100 Mb/s connection/activity). 
 

LEFT LED 

RIGHT LED 

 

 

3

 

SETTING 

3.1

 

MI485 

The MI485 communication interface does not need any setting for its operation; however, measuring instruments connected to 
RS485 communication should be set. Measuring instruments connected to RS485 net should have different addresses set (when 
purchased their address is 33). They should also have the same communication rate (at purcase it is 9600 bits/s). The MiNet 
program is recommended for parameter setting.. 
 

3.2

 

MI486 AND MI488 

Parameters for ethernet connection should be set for the MI486 and MI488 communication interfaces before the first application. 
Parameters are set by means of the Deviceinstaller program. Its installation and description of settings are described in item 3.2.2. 
The RS485 net connected to the MI488 interface should also be set. We recommend to set the net by means of the MI485 interface 
and the MiNet program (see item 3.1). The programs for setting the interfaces are avaliable on the CD marked MI48x. 
 

3.2.1

 

SETTING ETHERNET CONNECTION 

The communication interface should have a unique IP address in the ethernet net. Two ways of assigning the IP  are described 
below. 

Summary of Contents for MI485

Page 1: ...Instructions Manual Communication Interfaces MI485 MI486 MI488...

Page 2: ...TTING 4 3 1 MI485 4 3 2 MI486 AND MI488 4 3 2 1 SETTING ethernet CONNECTION 4 3 2 2 DeviceInstaller PROGRAM INSTALLATION AND INTERFACE SETTING 5 3 2 2 1 Setting fixed IP address 5 3 2 2 2 Communicatio...

Page 3: ...alue is written on the interface front label RS232 communication Connect it according to the table below Maximal length is 3 meters MI485 Computer DB9 Tx 26 Rx 2 Rx 24 Tx 3 GND 25 GND 5 RS485 communic...

Page 4: ...nt addresses set when purchased their address is 33 They should also have the same communication rate at purcase it is 9600 bits s The MiNet program is recommended for parameter setting 3 2 MI486 AND...

Page 5: ...a CD and choose Setup exe in the Device_Installer directory e g E Device_Installer Setup exe Follow recommended settings by the installation wizard After program installation restart the PC 3 2 2 1 S...

Page 6: ...MI486 MI488 3 2 2 2 Communication interface configuration 1 Click the selected interface type A window below is displayed 2 Click the Configure icon 3 Your own remarks regarding the interface can be w...

Page 7: ...6 MI488 7 4 Set communication parameters on the Ports tab 5 Click the Edit Settings key and write required communication parameters WARNING The rate that is set in a window below is a maximal rate for...

Page 8: ...I486 MI488 6 Set a corresponding local port on the Advanced tab If the communication interface is used together with the Com Port redirector program setting are described in continuation the local por...

Page 9: ...in MI488 communication interfaces via ethernet networks is also enabled with the programs designed only for communication via serial connection COM 3 2 3 1 Setting of virtual com port 1 Click the Star...

Page 10: ...nication Interfaces MI485 MI486 MI488 4 Click the Save key in the main dialogue window and confirm the data on the screen In this way the virtual COM port has been successfully set After setting the v...

Page 11: ...ogram If communication rate of 115200 bitov s is set try to select a smaller rate e g 57600 bits s 4 2 MI486 AND MI488 If communication with the measuring instruments cannot be established check the f...

Reviews: