ISIC DuraMON 7 User Manual Download Page 4

 

 

 

 

 

1

 

Features 

 

Congratulations on your purchase of a DuraMON 7”. This short form manual is designed to get 

you started working with your new DuraMON 7”. 

 

The DuraMON 7” series of Panel Computers are all designed for the demanding operating 

conditions at sea. 

 

The DuraMON 7” series are tested for full compliance to marine-standards IACS E10 and IEC 

60945. 

 

The DuraMON 7” comes with excellent brightness and contrast levels that, together with wide 

viewing angles, ensure a good readability thus making it very eye-friendly. For the best picture 

quality, always use a double shielded DVI or VGA cable with ferrites, like the one supplied with 

the unit.  

 

 

2

 

General considerations on Installation and 

Operation 

 

The DuraMON 7” is designed to work at conditions according to IEC 60945. However, keeping 

the temperature and vibration level at a minimum will extend the life time of the product. ISIC 

recommend operating this product at normal room temperature (20-25 °C), with the lowest 

level of vibration and humidity.  

 

Installation of the DuraMON 7” 

 

In order to obtain the best possible operating conditions, please note the following precautions. 

 

-

 

Room for cooling. 

When designing the cabinet/console for the DuraMON 7”, please ensure that air can 

flow freely around the cabinet, in order to avoid any unnecessary rise in 

temperature. If it is not possible to have an adequate natural airflow, use a fan to 

force the airflow to be higher. 

 

-

 

Mounting positions 

The DuraMON 7” is designed for both horizontal and vertical installation. 

 

-

 

Sunlight 

Avoid direct sunlight to keep temperature low by that improve lifetime.  

 

User Reference Manual – DuraMON 7” series 

PN: 07009-000 Rev A Page 4 

Summary of Contents for DuraMON 7

Page 1: ...User Manual DuraMON 7...

Page 2: ...t installed and used in accordance with the instructions advised by ISIC A S it may cause interference to radio communication The DuraMON series manufactured by ISIC A S is designed to comply with the...

Page 3: ...DURAMON 7 DROP IN 10 8 MECHANICAL OUTLINE DURAMON 7 FLUSH MOUNT 11 9 MECHANICAL OUTLINE DURAMON 7 RETROFIT 12 10 COMPASS SAFE DISTANCE 13 11 POWER CONSUMPTION 13 12 IN RUSH CURRENT 13 13 TROUBLESHOOT...

Page 4: ...work at conditions according to IEC 60945 However keeping the temperature and vibration level at a minimum will extend the life time of the product ISIC recommend operating this product at normal roo...

Page 5: ...onnector pin out 4 1 RS 232 Pin RS 232 SUB D 9 pol female 1 2 Monitor TX 3 Monitor RX 4 5 GND 6 7 8 9 Mating part SUB D 9 pole female Norcomp 172 E09 20201 or equivalent RS 232 DVI I 2 x PWR DC CHASSI...

Page 6: ...is 24V There are two independent galvanic isolated power inputs Mating part Weidm ller BLZP5 08HC 02 180F Pin Power in 1 0VDC 2 24VDC 4 3 USB Pin USB Standard A 1 Vcc 2 Data 3 Data 4 GND User Referen...

Page 7: ...power Galvanic isolated Power Consumption Ptyp 6 Watt Pmax 8 Watt DuraMON 7 Environmental Operating Temperature 15 to 55 C Storage Temperature 25 to 70 C Relative Humidity 8 to 95 non condensing DuraM...

Page 8: ...ght level one step when no OSD is active BYTE0 BYTE1 BYTE2 BYTE3 BYTE4 BYTE5 0x06 0x00 0x4B 0x4D 0x44 0x1E Reply from Monitor BYTE0 BYTE1 BYTE2 BYTE3 BYTE4 BYTE5 0x64 0x6F 0x77 0x6E 0x0D 0x0A 6 DDC CI...

Page 9: ...BYTE0 BYTE1 BYTE2 BYTE3 BYTE4 BYTE5 BYTE6 BYTE7 0x6E 0x51 0x84 0x03 0x10 0x00 0x5A 0xF2 VCP 12h Contrast Value range 0x00 0x64 Example Set Contrast to 0x32 50 BYTE0 BYTE1 BYTE2 BYTE3 BYTE4 BYTE5 BYTE...

Page 10: ...its mm Designed by KSC 24 6 2015 Mechanical outline DuraMon 7 Drop in NJS 24 6 2015 General tolerances 0 2 Hole position 0 1 Angle straightness and flatness DS ISO 2768 H Scale Drawing no Replaces 074...

Page 11: ...ral tolerances 0 2 Hole position 0 1 Angle straightness and flatness DS ISO 2768 H Scale Drawing no Replaces 07426 000 A Rev Subject ISIC A S Edwin Rahrs Vej 54 DK 8220 Brabrand Tlf 45 70207077 Web ww...

Page 12: ...Hole position 0 1 Angle straightness and flatness DS ISO 2768 H Scale Drawing no Replaces 07426 000 A Rev Subject ISIC A S Edwin Rahrs Vej 54 DK 8220 Brabrand Tlf 45 70207077 Web www isic dk This doc...

Page 13: ...7 85 13 Troubleshooting Problem Cause Solutions No picture on display No power connected Apply power Touch has an offset No grounding of the chassis Connect ground cable to chassis screw No calibrati...

Page 14: ...0159 69 IBAN for EUR DK48 0892 0003 0026 19 IBAN for USD DK26 0892 0003 0026 27 Contacts RFQ s By fax to 45 70 20 79 76 By mail to sales isic systems com Orders By fax to 45 70 20 79 76 By mail to ord...

Page 15: ...16 Revision history Rev A June 2015 First release User Reference Manual DuraMON 7 series PN 07009 000 Rev A Page 15...

Page 16: ...s of the warranty Monitor classification ISO 9241 307 2008 Allowed defects per type per million pixels Defect classes Pixel defects Cluster defect Type 1 Type 2 Type 3 total 2xN3a N3b Type 1 Type 2 Ty...

Page 17: ...tly dark Cluster A cluster consists of 5 x 5 pixels Cluster pixel defect type 1 Cluster pixel defect type 2 Pixels in a cluster area constantly lit Pixels in a cluster area constantly dark Cluster pix...

Page 18: ...ications Screen type Native resolution Number of pixels Pixel defect type 1 Pixel defect type 2 Pixel defect Type 3 total 2xN3a N3b Cluster defect type 1 and 2 Cluster defect type 3 WVGA 800x480 384 0...

Page 19: ...18 Appendix B Certificate of Conformity User Reference Manual DuraMON 7 series PN 07009 000 Rev A Page 19...

Page 20: ...Edwin Rahrs Vej 54 DK 8220 Brabrand Denmark Web http www isic systems com Email service isic systems com User Reference Manual DuraMON 7 series PN 07009 000 Rev A Page 20...

Reviews: