Setup Mode
© Rice Lake Weighing Systems
●
All Rights Reserved
9
2.1
B01-Machine Number
Configure Ethernet communication settings.
2.2
B02-Sales Mode
Parameter
Display
Description
Choices
B01-02
IP ADDR
B01-02-01
Enter the IP address of the scale. Enter the full 12-digit number
including leading zeros. Do not enter decimal points.
***.***.***.***
B01-02-02 Subnet Mask
Enter the subnet mask of the scale. Enter the full 12-digit number
including leading zeros. Do not enter decimal points.
***.***.***.***
B01-03-08 PING TO PC
Press the
Zero
key to execute the PING in order to test the
connection to the PC.
A long beep = success.
Five short beeps = failure.
--
B01-03
PC COM
B01-03-01
Enter the target address when executing a PING. Enter the full
12-digit number including leading zeros. Do not enter decimal
points.
***.***.***.***
B01-03-02 PORT NO
PC port number used for communication. Do not change.
8071
B01-03-03 COM CHK
COM check time (seconds). 600 Recommended.
30-9999 (0)
B01-03-04 TIME OUT
COM check time out (seconds). Do not change.
2
B01-03-05 FTP USER
Enter user name for FTP transmission. Press
Edit
and enter
character string edit.
--
B01-03-06 FTP PASS
Enter password (more than 8 characters) for FTP transmission.
Press
Edit
and enter character string - number and letters, no
special characters.
--
B01-03-08 PING TO PC
Press the
Zero
key to execute the PING in order to test the
connection to the PC.
A long beep = success.
Five short beeps = failure.
--
Table 2-1. B01 Machine Number Parameters
Parameter
Display
Description
Choices
B02-01
SALES MODE
B02-01 SALES MODE
Fixed at 1.
1: NO OPERATOR
Issue labels using the
key.
Table 2-2. B02 Sales Mode Parameters