background image

 

© International Scientific Group 2020 

Version 2020.01

 

 

 

 

 

 

 

5. Precautions 

 

1.  Please read the instruction manual carefully before using the unit. 
2.  The use of this unit must be in accordance with the specifications in this manual. 
3.  Do not use in flammable and explosive environments. 
4.  Ensure all doors and windows are closed during use. 
5.  The unit should be turned off and mains power disconnected for cleaning and 

 

maintenance. 

6.  It is strictly forbidden to cover or block the air inlet and outlet of the unit. 
7.  Do  not  insert  anything  into  the  front  of  the  unit through the  air  inlet  vent. This  may 

 

cause damage to the fan and can result in electric shock. 

8.   Avoid direct contact with liquid whilst operating. 
9.  When  repairing  or  cleaning,  ensured  the  power  is  turned  off  to  prevent  ultraviolet 

 

rays damaging the skin and eyes. 

10. The ultraviolet germicidal lamp should be replaced after 5000 hours of use. 

 

 

 

6. General troubleshooting 

 

Failure 

Action 

 

 

Unit does not turn on  

1. Check fuse in the plug 

 

 

2. Check mains power lead is connected 

 

 

 

UV lamp not working 

1. The ballast of UV germicidal lamp may be damaged 

 

 

2. The UV germicidal lamp may be burnt out 

 
 

 

 

1. The fan motor may be burnt out 

Fan not working 

 

2. The motor capacitor may be burnt out 

but power on 

 

 

3. Check no foreign objects obstructing fan 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Viralair-UV

Page 1: ... International Scientific Group 2020 Version 2020 01 Viralair UV Steriliser User Manual ...

Page 2: ...ientific Group 2020 Version 2020 01 Content 1 Introduction 2 Technical 3 Product Use 4 Operation 5 Precautions 6 General Troubleshooting 7 Maintenance 8 Replace Bulbs 9 Warranty And Repair 10 Transportation And Storage ...

Page 3: ...is Class II Type B general equipment 4 Disinfection space 80m 5 Circulating air volume 800m h 6 UV leakage outside the unit 5µw cm 30cm away from the unit 7 Noise 55dB 8 Input power 260W 3 Product Use The UV air steriliser is suitable for indoor air disinfection in medical institutions production workshops with hygienic requirements public places offices care homes and domestic environments There ...

Page 4: ...nt of the unit through the air inlet vent This may cause damage to the fan and can result in electric shock 8 Avoid direct contact with liquid whilst operating 9 When repairing or cleaning ensured the power is turned off to prevent ultraviolet rays damaging the skin and eyes 10 The ultraviolet germicidal lamp should be replaced after 5000 hours of use 6 General troubleshooting Failure Action Unit ...

Page 5: ...enclosure 4 Replace with new bulb and secure with the wire tie at the top 5 Replace the outer casing and secure with screws Note discarded UV bulbs should be safely disposed of in accordance with waste disposal guidelines 9 Warranty and repair 1 This UV air steriliser is supplied with a 12 month warranty from the date of purchase 2 For the maintenance and replacement of parts please contact ISG Fu...

Reviews:

Related manuals for Viralair-UV