iMC-S8
– operating instruction
page - 33
Use of the controller with Remote
Using iMC-S8 with Remote (ProNC) via serial interface:
1. Start control software
Remote.
If you don’t have activated
Remote
you have to do
it now.
2. After installation of
Remote
for a specific control (in this case IMC4) all module
DLL’s for the motion control, I/O module, spindle module and security circuit
module are set correctly. You only have to set the parameters to your machine
configuration.
Click in the main menu to the entry Settings
Control
The dialog shows all
active and used
modules in a list.
Mark the line “Motion
Control” and click on
button “Setup” on the
right side to show the
settings for
communication and axis
kinematics.
Over the different register cards you
can change the parameters like axis
direction, spindle gradient, gear etc.
for each separate axis. Over the
register card “Data transmission” you
can change the used COM Port of the
control computer.
3.
If you have set all parameters close the dialog with the button „OK“.
Click on button “Close & Initialize” in the “Control module and settings” dialog to
take effect the new settings and reinitialize the control.
4. Perform a software reset
and a reference run
to check correct
behaviour of the machine /system.