4.1.6 Bank select switch
The setting of the addresses of the iseg Multi-Channel HV modules is done by setting the address pins at the system connector.
From these address pins the module gets the basic information to process the relating identifier bits. In the iseg system crate the
address pins are set in same for all modules in the crate. It is set via a so called “Bank Select” switch at the front side of the crate
controller.
Crate 1
Control
Crate 2
Control
Crate 3
Control
Bank
Select
Bank
Select
Bank
Select
Switch: 0
Switch: 1
Switch: 2
Figure 2: Example structure Crate
4.2 Forced air cooling
The crate offers an internal forced air cooling with temperature dependent speed regulation by the crate controller. The fresh air
intake is on the bottom, for propper ventilation it needs to be sure that the airflow is not blocked.
INFORMATION
INFORMATION
Further it is recommended to cover unused module slots with blind front panels to provide optimal airflow and
cooling performance.