background image

S p e z i a l e l e k t r o n i k     G m b H

 

iseg Spezialelektronik GmbH 

Email: [email protected] 

Phone  ++ 49 (0)351 / 26 996 - 0 

Bautzner Landstr. 23 

http://www.iseg-hv.com 

Fax 

++ 49 (0)351 / 26 996 - 21 

D - 01454 Radeberg / Rossendorf 

Germany 

Crate with Power Supply 

ECH 238_1200W 
ECH 238_1200W-UPS 

Operator’s Manual 

Contents 

1. General information
2. Technical Data
3. Connections, pin assignments

3.1. Module station 
3.2. External CAN-Bus 

4. Front panel / Operation

Attention! 

-It is not allowed to use the unit if the covers have been removed.

-We decline all responsibility for damages and injuries caused by an improper use of the module. It is highly
recommended to read the manual before any kind of operation.

Note 

The information in this manual is subject to change without notice. We take no responsibility for any error in the 
document. We reserve the right to make changes in the product design without notification to the users. 

Filename ECH238_1200W as of 2011-07-04 

Via Acquanera, 29   

22100  Como

tel.  031.526.566 (r.a.)  fax  031.507.984

[email protected]   

www.calpower.it

Summary of Contents for ECH 238 1200W

Page 1: ...eration Attention It is not allowed to use the unit if the covers have been removed We decline all responsibility for damages and injuries caused by an improper use of the module It is highly recommended to read the manual before any kind of operation Note The information in this manual is subject to change without notice We take no responsibility for any error in the document We reserve the right...

Page 2: ...red during the operation of the unit 2 Technical data ECH 238 M AC supply voltage 110 240 V max 12 A fuses double sided DC supply voltages 24 V up to 50 A 5 V up to 5 A Total Power max 1200 W Floating max difference of voltage between PE and internal GND V 30 V clamped via antiparallel suppressor diode with VZ 56 V Mechanical layout 19 Standard BIN 6 U ca 450 mm depth Module slot depth 220 mm CAN ...

Page 3: ...ront p a Mod_addr module address b22 hard wired 31 b Bank_addr module address b23 bank switch on front p c GND a Mod_addr module address b20 hard wired 32 b Mod_addr module address b21 hard wired c GND 3 2 External CAN Bus The external CAN Bus to control the iseg HV module CAN HV and the crate with the built in CAN crate controller CAN CC is connected through RJ45 connectors on the front panel The...

Page 4: ... built in multichannel module with option _SL is active then an output voltage in any channel of it is only present if this safety loop is closed STATUS LED green red green indicates POWER ON 24V DC O K and no CAN error and Option UPS Battery on float charge STDBY AC supply ON remote control possible POWER ON ON OFF switch 24V DC Supply AC Power ECH x38 SL1 SL2 0 CAN HV POWER ON 1 BANK SELECT 2 ST...

Reviews: