background image

34

35

EZYiD

®

 Retro-fit System - Issue A - August 2019

EZYiD

®

 Retro-fit System - Issue A - August 2019

All Tags, Cable Ties, Stickers and Universal Moulded Tags are passive 

(passive components are electronic components that do not require a 

source of energy to perform their intended functions).

10: Lifespan & Warranty:

CSP Distribution Pty. Ltd. guarantees that EZYiD products will be free 

from  material  defects  caused  by  workmanship  or  production.  This 

guarantee extends to and no more than twelve (12) months from the 

date of purchase. 

Our  goods  come  with  guarantees  that  cannot  be  excluded  under 

the Australian Consumer Law.  You are entitled to a replacement or 

refund for a major failure and compensation for any other reasonably 

foreseeable loss or damage.  You are also  entitled to have the goods 

repaired or replaced if the goods fail to be of acceptable quality and 

the failure does not amount to a major failure.

The warranty that covers this product does not extend to damage or 

malfunctions caused by improper installation, use, storage or improper 

modifications or repairs on the product. 

To  claim  warranty,  the  purchaser  must  notify  CSP  Distribution  Pty. 

Ltd. of the material defect immediately after its discovery, or within 

a timeframe that would be deemed  as reasonable.  After notification 

has  been  made,  the  purchaser  must  not  use  or  attempt  to  use 

the  defective  product  until  CSP  Distribution  Pty.  Ltd.  has  had  the 

opportunity to assess the product’s defects and respond appropriately 

to the complaint.  Any use of the product after notification may result 

in the claim becoming void. 

For warranty support please contact [email protected] 

11: Global Service & Support

Web Support:

Basic reader FAQ can be found at www.ezyid.com. Alternatively, use 

our online contact portal to speak to customer support regarding any 

other queries you may have regarding your EZYiD Reader.

Telephone Support:

For Australian or International support, call +61 8 6146 0170 (calls are 

charged at standard rate)

Alternatively, please contact your nearest EZYiD reseller.

12: Disposal

Each country has specific legislation in place, relating to the responsible 

disposal of lithium batteries.  When disposing of your EZYiD Reader, 

please consult your local authority for compliance advice.

13: Feedback

Your  feedback  is  crucial  to  the  continual  improvement  of  our 

documentation and products.  To provide feedback about this manual 

or the EZYiD Reader and/or Tags, please contact:

CSP Distribution Pty. Ltd.

Customer Service 

[email protected] 

14: Legal Notices

CSP  Distribution  Pty.  Ltd.  declines  every  responsibility  in  relation  to 

possible  damages,  losses  of  income  or  any  other  damage  resulting 

from  the  use  of  this  product.    The  content  of  this  manual  cannot 

be  brought  anywhere  without  the  permission  of  the  producer.    The 

technical  specifics  of  the  product  and  the  information  brought 

Summary of Contents for EZYiD

Page 1: ...1 EZYiD Retro fit System Issue A August 2019 EZYiD Retro fit System...

Page 2: ...examples and diagrams in this manual are included solely for illustrative purposes NOTE Reproduction of the contents of this manual in whole or in part without written permission of CSP Distribution P...

Page 3: ...information about the features of the Reader how to install configure operate and maintain it together with troubleshooting information Before working with the EZYiD Reader users should familiarise th...

Page 4: ...Antenna Central Button LED Blue EZYiD Logo Body of Reader LED Orange 7 8 9 10 11 Product Information Label Serial Number Charging Port Identification Numbers Product Regulatory Information Not to Sca...

Page 5: ...Low Flashing Blue Light when charger cable is connected to device and to power source Reader is charging Solid Blue Light when charger is connected to device and to power source Reader is fully charge...

Page 6: ...n the central diamond shaped button for one 1 second 2 An orange LED will appear on the right side 3 The LED will move to the left and appear in blue Two 2 beeps will sound The blue LED will remain on...

Page 7: ...or mobile phone to pair the Reader to your personal device Your Reader can only be paired to one computer tablet or mobile phone at a time in order for it to function correctly If you wish to pair th...

Page 8: ...le press of the central button the device is on the tag is readable and the reader is able to read the tag but your Reader is not paired to a computer tablet or mobile device Therefore data informatio...

Page 9: ...ystem Issue A August 2019 5 5 How to Hold the EZYiD Reader The EZYiD Reader should be held comfortably in one hand ensuring that the antenna is not covered Care should be taken not to press hold or da...

Page 10: ...cated Different LED and sounds will notify you of the outcome Hold the antenna closely 2 3mm over the Tag Sticker Cable Tie or Universal Moulded Tag which needs to be read Press down on the central bu...

Page 11: ...Application Tags 6mm 2mm Tags Tags are low profile with a depth of 2mm and diameter of 6mm Tags can be applied to assets using a commonly available Contact Adhesive or Two part Epoxy Resin not supplie...

Page 12: ...System Issue A August 2019 Cable Ties Cable Tie Cable Ties are fitted with an EZYiD Tag near the buckle end of the tie thus allowing the Cable Ties to be fitted in the usual manner with any excess le...

Page 13: ...ssue A August 2019 25mm 25mm Stickers Stickers Stickers are 25mm x 25mm 1 x1 with a low profile of 1mm and contain a special flat RFID tag Stickers are supplied with a self adhesive backing and can be...

Page 14: ...t 2019 Universal Moulded Tags Universal Moulded Tags Universal Moulded Tags are 19mm x 10mm x 5mm 3 4 x 25 64 x 13 64 and can be fitted to assets by using a cable tie nail screw pop rivet or glue The...

Page 15: ...rea of the asset where they will not interfere with the function of the asset Care should also be taken to position the tag away from the high wear areas of the asset in order to best defend the tags...

Page 16: ...emicals and other environmental conditions that could possibly cause damage to the Reader Damage to the Reader could result in a lack of integrity in operating functions CAUTION The EZYiD Reader case...

Page 17: ...s connected Consult the dealer RoHS Conformity BlueBerry has been realized using materials and constructive processes conforming to the limits imposed by the directive 2003 108 CE RoHS concerning the...

Page 18: ...ot use or attempt to use the defective product until CSP Distribution Pty Ltd has had the opportunity to assess the product s defects and respond appropriately to the complaint Any use of the product...

Page 19: ...responsibility of the user to read and understand these instructions prior to use If the Reader is used in a manner contrary to the specification of the manufacturer as defined in this manual the pro...

Page 20: ...38 39 EZYiD Retro fit System Issue A August 2019 EZYiD Retro fit System Issue A August 2019 Notes Notes...

Page 21: ...carborough Beach Road Osborne Park WA 6017 www ezyid com 61 8 6146 0170 support ezyid com International Safety Components Ltd Unit 1 Plot 2 Llandygai Industrial Estate Bangor Gwynedd LL57 4YH United K...

Reviews: