USE AND MAINTENANCE MANUAL

428000670

037

EN

  

PROFESSIONAL GELATO CABINETS

 INSTALLATION

This manual supplies the information necessary for correct unpacking, procedures for 

positioning and connection to mains electricity.

1 STORAGE AND UNPACKING

The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas 

away from the elements and direct sunlight, at a temperature between 0 and +40 °C.

 

The appliance should only be moved by qualifi ed personnel operating 

forklift trucks, the power of which should be suited to handling the weight 

of the product. 

During said operation the appliance MUST placed on the special pallet supplied.

Unpack the appliance by removing the screws fi xing it to the pallet.

All packaging materials are recyclable and should be disposed of in accordance with local regulations. 

Please destroy "plastic" bags to prevent them from becoming hazardous to children (suffocation).

2 INSTALLATION - POSITIONING - ENVIRONMENTAL CONDITIONS

Attention

A dry room that can be ventilated is the suitable location for the appliance's installation. 

There should be a good air fl ow around the compressor/condensing unit. 

Therefore the area around the unit should not be obstructed by boxes or other objects.

Position the appliance away from heat sources (radiators, stoves of all types, etc.)  and away from 

the effects of continuous currents of air (e.g. caused by fans, air conditioning vents, etc.). 

If it is unavoidable to install near a heat source, use a suitable insulating plate,

Also avoid exposure to direct sunlight; all of this causes the temperature inside the refrigerated 

compartment to rise with negative consequences on operation and energy consumption. 

Do not use the appliance outdoors and do not leave it exposed to rain.

3 ELECTRIC CONNECTION

Attention

Check that the network voltage matches the one displayed on the identifi cation plate of the 

appliance, and that the power is adequate. 

Check on the socket that the power supply voltage provides rated voltage (±10%) when you start 

up the compressor.

The plug should be directly connected to the electrical socket. 

It is forbidden to connect the plug to the socket by means of multiple socket extensions or 

adaptors.

The plant power supply socket must be fi tted with a disconnection device from the mains electricity 

(dimensioned to the load and in compliance with Standards in force), which guarantees complete 

disconnection in category III (3) over-voltage conditions and therefore protects the circuits against 

earth faults, overloads and short circuits.

Do not route the electricity cable in passageways.

Attention

Earthing is necessary and mandatory by law.