press button. To modify an entry, click entry and change as needed. If the current time is within defined
entry, status will change to active, otherwise it is inactive. If active, lights are automatically switched on.
After performing setup or any changes to this section, click „SAVE SETTINGS” to save configuration to
system.
3.8.4
KNX communication objects
Light feature uses two communication objects. One to receive actual status of the channel and second to
control output from external trigger.
Group
Address
Data Point Name
Data Point Type
Description
10/0/3
LVLØ Light Control (Send 1/0)
control pulse
edge 1/0
1 bit
W
1.001
Actuator to control "LIGHT" output. Toggle current output status
when pulse edge telegram (0/1) will be received on this input. Status
feedback will be send when output changes state.
10/0/4
LVLØ Light Status Feedback (1=On, 0=Off)
display of
status
1 bit
R
1.001
Status feedback of "LIGHT" output. Feedback is sent cyclically to bus
every 600s.
NOTE:
Details are documented in “KNX bus communication” section 6.
For examples of KNX communication see section 6.4.
3.9
Pool cover and pool cover drain
3.9.1
Overview
All kinds of electrically-operated motor rollers, shutters, awnings, venting louvers or similar blinds for 230
V AC mains voltage (or DC in combination with optional LVLØ DC Cover Extension module) can be controlled
by LVLØ. Cover can be then controlled from mobile application via password protected section or via KNX
integration. There is also a possibility to enable secure blocking of attractions when pool cover is closed.
For overflow edge pool equipped with surrounding cover, the cover drain feature can be used to reduce
water level when the cover is closed. This can prevent the cover to move from his position (strong wind,
etc.).
3.9.2
Electrical connection
The “POOL COVER” output is powered from build-in circuit breaker. This has
“LVLØ System” sign of devices front panel (see picture). This output allows
the control of electrically-operated motors like roller shutters, awnings,
venting louvers or similar motors, suitable for 240 V AC mains voltage.
Based on command (UP or DOWN – cover open or closed), the output will
be powered with AC power for the time set (see configuration section
below).
UP – Open – Phase
DOWN – Close – Phase
N – Neutral
PE - Ground
For detailed specification refer to
connector position details are in section 2.2.2.