NO) mechanism. Connect push button electrical switch that operates by the switch, making contact with
the electronic system when the button is pressed and breaks the current process when the button is
released. You can connect more pushbuttons in parallel to one input.
SWITCH AUX 1 - connector position details in section
2.2.2.,
Connector 20.
Use potential free contacts:
1 – 1
st
terminal
2 – 2
nd
terminal
SWITCH AUX 2 - connector position details in section
2.2.2.,
Connector 21.
Use potential free contacts:
1 – 1
st
terminal
2 – 2
nd
terminal
NOTE:
Do not connect any external voltage to these inputs, since doing so may damage the device.
If control via power output is needed, use signaling relays and connect “NO” contacts to “SWITCH
AUX 1 or 2” input.
Do not connect either the “Neutral” or “Line” signal of the 110-415 VAC to connector pin’s 1 or 2!
3.7.4.3
Configuration, AUX1 & AUX2 button assignment
AUX button assignment has to be performed via LVLØ mobile application in Service section. Select AUX,
Lights and Cover.
AUX1 button : <AUX1, AUX2, none> select function to trigger with AUX 1 (air switch or pushbutton) input.
AUX2 button : <AUX1, AUX2, none> select function to trigger with AUX 2 (air switch or pushbutton) input.
AUX1 sequencer : <enabled, disabled> if enabled, air switch connected to “Switch AUX1” or pushbutton
connected to a terminal “Switch AUX1” will be able to resolve multiple click. With this feature it is
possible to control AUX1, AUX2 and lights with only one button:
a)
on click will (1) switch on/off AUX1,
b)
two clicks (2) will switch on/off AUX2,
c)
three (3) clicks will switch on/off lights.
After performing setup or any changes to this section, click „SAVE SETTINGS” to save configuration to
system.
3.7.5
KNX communication objects
Each of the LVLØ AUX outputs uses two communication objects. One to receive actual status of the output
and second to control output from external trigger.
Group
Address
Data Point Name
Data Point Type
Description
10/0/8
LVLØ AUX1 Control (Send 1/0)
control pulse
edge 1/0
1 bit
W
1.001
Actuator to control "AUX1" output. Toggle current output status
when pulse edge telegram (0/1) will be received on this input.
Status feedback will be send when output changes state.
10/0/9
LVLØ AUX1 Status Feedback (1=On, 0=Off)
display of
status
1 bit
R
1.001
Status feedback of "AUX1" output.