RJ-45 Input (Data and Power)
RJ-45 Output (Data Only)
Symbol
Description
Symbol
Description
1
BI_DA+
Data BI_DA+
BI_DA+
Data BI_DA+
2
BI_DA-
Data BI_DA-
BI_DA-
Data BI_DA-
3
BI_DB+
Data BI_DB+
BI_DB+
Data BI_DB+
4
BI_DC+ (Vdc+)
Data BI_DC+ and Feeding power(+)
BI_DC+
Data BI_DC+
5
BI_DC- (Vdc+)
Data BI_DC- and Feeding power(+)
BI_DC-
Data BI_DC-
6
BI_DB-
Data BI_DB-
BI_DB-
Data BI_DB-
7
BI_DD+ (Vdc-)
Data BI_DD+ and Feeding power(-)
BI_DD+
Data BI_DD+
8
BI_DD- (Vdc-)
Data BI_DD- and Feeding power(-)
BI_DD-
Data BI_DD-
RJ-45 Output (Data and Power)
RJ-45 Output (Data Only)
Symbol
Description
Symbol
Description
1
Rx+
Data Receiv e
Rx+
Data Receiv e
2
Rx-
Data Receiv e
Rx-
Data Receiv e
3
Tx+
Data Transmit
Tx+
Data Transmit
4
Vdc+
Feeding power(+)
NC
Not Connected
5
Vdc+
Feeding power(+)
NC
Not Connected
6
Tx-
Data Transmit
Tx-
Data Transmit
7
Vdc-
Feeding power(-)
NC
Not Connected
8
Vdc-
Feeding power(-)
NC
Not Connected
RJ-45 Input (Data and Power)
RJ-45 Output (Data Only)
Symbol
Description
Symbol
Description
1
BI_DA+ (Vdc+)
Data BI_DA+ and Feeding power(+)
BI_DA+
Data BI_DA+
2
BI_DA- (Vdc+)
Data BI_DA- and Feeding power(+)
BI_DA-
Data BI_DA-
3
BI_DB+ (Vdc-)
Data BI_DB+ and Feeding power(-)
BI_DB+
Data BI_DB+
4
BI_DC+
Data BI_DC+
BI_DC+
Data BI_DC+
5
BI_DC-
Data BI_DC-
BI_DC-
Data BI_DC-
6
BI_DB- (Vdc-)
Data BI_DB- and Feeding power(-)
BI_DB-
Data BI_DB-
7
BI_DD+
Data BI_DD+
BI_DD+
Data BI_DD+
8
BI_DD-
Data BI_DD-
BI_DD-
Data BI_DD-
RJ-45 Input (Data and Power)
RJ-45 Output (Data Only)
Symbol
Description
Symbol
Description
1
Rx+ (Vdc+)
Data Receive and Feeding power(+)
Rx+
Data Receiv e
2
Rx- (Vdc+)
Data Receive and Feeding power(+)
Rx-
Data Receiv e
3
Tx+ (Vdc-)
Data Transmit and Feeding power(-)
Tx+
Data Transmit
4
NC
Not Connected
NC
Not Connected
5
NC
Not Connected
NC
Not Connected
6
Tx- (Vdc-)
Data Transmit and Feeding power(-)
Tx-
Data Transmit
7
NC
Not Connected
NC
Not Connected
8
NC
Not Connected
NC
Not Connected
Q
uick
S
tart
G
uide
iPS2
–
Industrial Gigabit PoE Splitter
Introduction
Specifications
Connector and Pin Definition
The iPS2 is a high power PoE Splitter for use in Power over Ethernet systems. With
Ethernet Input (data + power) port and Output (data only) port, the iPS2 may split
power from existing LAN cable and convert up to 24VDC/1.25A for power hungry
applications such as Wireless APs, Security cameras and IP Phones. The internal
current limit, short-circuit and overload protection are implemented for use as a DC
power supply.
iPS2 Model
Physical
Ports
10/100/1000 Base-T(X) Ports
PoE Definition 1
1000Base-T
Features
Fully compliant with IEEE802.3at/af standard
Supports 10/100/1000Base-T(X) for PoE In and Data Out
Power Isolation and Short Circuit Protection for Power Output
Auto protection for Over Voltage Power Input
Supports Power Outputs up to 30Watts
in RJ45 Auto MDI/MDIX
1
10/100/1000Base-T(X) P.S.E.
Port in RJ45 Auto MDI/MDIX
1
Operating Voltage
Input Voltage
36 ~ 57 VDC on RJ45 connector
IP-40 Galvanized Steel Case Design
DIN-Rail and wall-mount enabled
Output Power
24V @ 1.25A max. (30 Watts)
LED indicators
PWR / Ready: 1 x LED
24V @ 0.45A max. (10.8 Watts)
10/100 Base-T(X)
Connections
Power indicator
Blue On: Power is on and
functioning Normally.
Green On: Power is on and
functioning Normally.
Connections of Splitter
Protection
Short Circuit Protection
Present
Over Load Protection
Present
Isolation Protection
1500V
Physical Characteristic
Enclosure
IP-40
Note: pins 7 and 8 (-Vdc) should not be shorted to ground
Dimension (W x D x H)
26.1(W) x 70(D) x 95(H)mm (1.03x 2.76 x 3.74inch.)
PoE Definition 2
Weight (g)
Environmental
Storage Temperature
250 g
-40 to 80
o
C (-40 to 176
o
F)
200 g
1000Base-T
Operating Temperature
-40 to 85
o
C (-40 to 158
o
F)
Operating Humidity
5% to 90% Non-condensing
Power Connection Guide
G
Frame Ground
Regulatory Approvals
EMI
EMS
Safety
FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EF T),
EN61000-4-5 (Surge), EN61000-
4-6 (CS),
EN61000-4-8, EN61000-4-
11
EN60950-1
10/100 Base-T(X)
V-
V-
V+ V+ OUT PUT DC 24V
Warranty
5 years
Power
Output
24 VDC
Note: pins 3 and 6 (-Vdc) should not be shorted to ground
QSG