background image

GSM модем iRZ TC65 Lite

User Manual

19

3. Emergency Situations

To simplify the use of the modem, tracking of emergencies is provided.

3.1. Emergency 1 (input power supply invalid)

Emergency 1 arises upon deviation of the input voltage from the allowed value. In such case the

modem stops the operation: disconnects the GSM module power supply. It signals with the red LED
about the emergency situation (turned on continuously). Escaping from the emergency situation is
possible only after restoring of the input voltage.

3.2. Emergency 2 (module power supply invalid)

Emergency 2 arises in the event of deviation of the power supply voltage of the GSM module

from the allowed value. In such case the modem stops the operation: disconnects the GSM module
power supply. It signals with the red LED about the emergency situation (0.5 s on / 0.5 s off).
Escaping from the emergency situation is possible only after restoring of the power supply voltage
of the module within 10 seconds from the time when the emergency situation occurred. If the power
supply voltage of the module stays incorrect within 10 seconds (with correct input voltage), the
modem jumps to the standby mode – the module power supply is disconnected, the emergency
indication persists. Escaping from the standby mode is possible only after full disconnection of
power supply.

In case of any repeated emergency after restarting of the modem, the modem is to be repaired.

3.3. Emergency 3 (GSM module not started)

Emergency 3 occurs in the event where the GSM module is not started.  Red LED signaling

about the emergency situation: 0.25 s on / 0.25 s off / 0.25 s on / 1 s off. Escaping from the
emergency  situation  is  possible  only  after  successful  start  of  the  GSM  module.  In  case  of  10
consecutive failed attempts to start the module (15 seconds), the modem jumps to the standby mode
– the module power supply is disconnected, the emergency indication persists. Escaping from the
standby mode is possible only with full disconnection of the power supply.

In case of any repeated emergency after restarting of the modem, the modem is to be repaired.

3.4. Emergency 4 (COM port not available)

Emergency 4 arises upon the unavailability of the COM port of the GSM module. Red LED

signaling on the occurrence of an accident: 0.25 s on / 0.25 s off / 0.25 s on / 0.25 s off / 0.25 s on / 1
s off. Escaping from the emergency situation is upon the availability of the COM port of the GSM
module. In the event of 10 consecutive failed attempts (20 seconds), the modem jumps to the
standby mode – the module power supply is disconnected, emergency indication persists.

In case of any repeated emergency after restarting of the modem, the modem is to be repaired.

Summary of Contents for TC65 Lite

Page 1: ...TC65 Lite GPRS class 12 GSM modem USER MANUAL...

Page 2: ...ication 10 2 Connection Setting Up and Control 11 2 1 Functional Diagram 11 2 2 Connection Operation Mode 11 2 3 GPRS Setting Up 12 2 4 Control Restarting and Power Off 12 2 5 Menu Mode 13 2 6 Program...

Page 3: ...can cause interference for medical equipment turn off the terminal in aircrafts Take measures against accidental activation turn off the modem in the vicinity of gas filling stations chemical enterpr...

Page 4: ...a LED indicator to track the connection status 1 2 Configuration Complete set of the GSM modem iRZ TC65 Lite terminal TC65 Lite label factory box 1 3 Parameters Basic parameters frequency ranges GSM...

Page 5: ...9 to 27 V absorbed current o with power supply voltage 12 V 400mA o with power supply voltage 24 V 200mA Physical parameters size max 70 74 33 mm weight max 100 g operating temperature range 30 to 60...

Page 6: ...2 Fig 2 4 1 Front view Fig 2 4 2 Back view On the figures 2 4 1 and 2 4 2 the digits signify the following 1 USB connector type B for data cable connection 2 LED indicator of status green and emergen...

Page 7: ...the connector pins Contact Signal Direction Purpose 1 DCD Modem PC Availability of carrier wave 2 RXD Modem PC Data reception 3 TXD PC Modem Data transmission 4 DTR PC Modem Availability of data rece...

Page 8: ...r Supply Connection The connector is used for connection of power Table 2 5 2 Purpose of the power supply connector pins Contact Signal Purpose 1 GND system housing 2 not used 3 not used 4 not used 5...

Page 9: ...nect to the control device The USB port does not have priority over the COM port the COM port becomes deactivated Table 2 5 3 Purpose of the USB connector pins Contact Signal Purpose 1 V BUS 5 V is us...

Page 10: ...s off 75 ms on 3 s off GPRS connection is installed 500 ms on 50 ms off Data transmission is underway 250 ms on 10 s off Modem is in power standby mode alarm clock mode 250 ms on 250 ms off Programmin...

Page 11: ...n cable RS232 or USB to the antenna connector Fig 2 4 2 Thereupon you need to feed power supply to the modem through the connector RJ11 Fig 2 4 1 Note GSM antenna commutation cables and electrical pow...

Page 12: ...where XX is the number of minutes in hexadecimal representation 255 max in which the module must be started jumping to the operation mode If XX 0 it should not be started If the command is accepted su...

Page 13: ...ter In case of incorrect input ERROR is indicated There is no difference between the entered uppercase and lowercase characters After input of the command P1 you jump to the statistics viewing menu Po...

Page 14: ...epending on whether or not the response is received restarts the module This function is disabled on default Note Java application can take off this COM port resulting in constant module restarting wi...

Page 15: ...on of the SIM tray the modem jumps to the operation mode 2 6 Programming Mode The programming mode is used to change update the software of the modem microcontroller The software is updated via the in...

Page 16: ...Select the port number of the Com port to which the modem is going to be connected Fig 2 Fig 2 3 Connect the modem without the SIM tray to the computer Feed power supply to the modem The modem is to...

Page 17: ...17 4 Select the new weaving file by clicking the File button A window will appear Fig 4 Fig 4 5 Select the new weaving file Click Open Upon successful loading of the file the program window is to disp...

Page 18: ...y the window is to display the same as on Fig 6 Fig 6 7 Click the Start button Thereupon the modem will exit from the programming mode the COM port will close Fig 7 7 8 Close the program Insert the SI...

Page 19: ...scaping from the standby mode is possible only after full disconnection of power supply In case of any repeated emergency after restarting of the modem the modem is to be repaired 3 3 Emergency 3 GSM...

Reviews: