20
3.
Hardware board version.
4.
Device name
– a unique device name containing 4 characters (digits and Latin letters). It is specified in
each SMS message
1
sent by the modem. The device name is used to distinguish SMS messages from
different modems. Case-insensitive: That is to say
aaaa
and
AAAA
– are identical names. Default value –
name.
5.
Login
– a string of 4–16 characters (digits and Latin letters, case sensitive), unique for each device. It can
be used for the modem authentication on a standard server (not iRZ Collector) if IMEI-based authentica-
tion is not sufficient. In addition, it can be used for iRZ protocol-based authentication (for more details, re-
fer to section
"Authentication of Connecting Clients"
). By default the modem login is equal to the modem
IMEI value.
SIM Cards Key Attributes
1.
Mobile network carrier settings:
APN (Internet access point name);
Login (user name);
Password.
Request for network settings at the mobile operator of your SIM card.
2.
PIN code (required if PIN code request is activated on the SIM card)
Key Attributes (for the modem-client operation)
1.
Server IP address
– the server IP address to which the modem-client is to be connected and transmit data
from an external device. It is required to specify a public static IP address of the data collection server or
network gateway (if the data collection server is in the local network behind the gateway). In the latter
case it is required to set up port forwarding from the gateway IP port to the server data collection IP port. If
you rent an APN from a service provider, it is required to specify the private address of the data collection
server in the IP address field. The address is 4 bytes long, consists of four decimal numbers, each ranging
from 0 to 255, separated by dots. For example, 83.58.124.13
2.
Server port is a network port of data collection server where it waits for connection of client modems. Val-
ue
– 0 to 65000. This port should not be used by other services. If data collection server is located in the
local network behind network gateway, it is required to set up port forwarding from the gateway IP port to
the IP port of the server data collection.
If you plan to use the backup server, it is required to enter its IP address and port and authorize its use.
Key Attributes (for the server modem operation)
1.
Incoming port is a network port of the modem-server where it waits for connection of clients. Value
– 0 to
65000. This port should not be used by other services.
1
For example, the modem can send SMS messages in case of connection loss or on signals from external outputs.