background image

DVS

4040 Instruction Book 

Revision 1

 

www.irtelectronics.com 

Page 5 of 15 

4040

DVS_ib_Rev1.doc 

Technical Specifications 

 

IRT Eurocard module 

Type DVS

4040 

 

Signal inputs: 

Number 5. 
Type 

270 Mb/s SDI or ASI 

Equalisation 

Automatic to 200 metres on each input. 

 

Automatic muting of inputs without signal. 

Impedance 75 

 

Signal outputs: 

Type 

SDI/ASI 

2 x 800 mV 

±

10% into 75 

 

Control inputs/outputs: 

Type 

5 bit BCD coded parallel TTL level. 

 or 
 

individual grounding contacts. 

Number 

1 input & 1 output. 

 

Performance: 

Switching 

Timing derived from a local monostable signal. 

Return loss 

>15 dB 5 MHz to 270 MHz. 

DC offset 

0 V 

±

0.5 V. 

Rise time 

between 0.75 and 1.5 ns. 

 

Power Requirements 

28 Vac CT (14

0

14) or 

±

 16 Vdc. 

Power consumption 

<125 mA. 

 

Connectors:

 SDI/ASI 

BNC. 

 

Control 

Plug in 10 pin HE14 dual IDC. 

Other: 

Temperature range 

 50° C ambient. 

Mechanical 

Suitable for mounting in IRT 19" rack chassis with input, output and 
power connections on the rear panel. 

Finish:  

Front panel 

Grey background, black lettering & red IRT logo. 

 Rear 

assembly Detachable 

silk

screened PCB with direct mount connectors to Eurocard 

and external signals. 

Dimensions  

6 HP x 3 U x 220 mm IRT Eurocard. 

 

Supplied accessories 

Rear connector assembly including matching connectors for control 
inputs & outputs. 

 

Optional accessories 

TPD

3010 front panel LED tally panel. 

 CPS

3050 local control conversion with 5 pushbuttons & tally LED’s. 

 CPS

9001 remote control panel with 5 pushbuttons & tally LED’s. 

 CPS

1050 remote control panel with 10 pushbuttons & tally LED’s. 

 CPS

1052 remote control panel with 20 pushbuttons & tally LED’s.

 

 SMU

4000 plug

in SNMP Management Information Base (MIB) module. 

 
 

Due to our policy of continuing development, these specifications are subject to change without notice.

 

 

Summary of Contents for DVS?4040

Page 1: ...esigned and manufactured in Australia IRT can be found on the Internet at http www irtelectronics com I R T Electronics Pty Ltd A B N 35 000 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA Nati...

Page 2: ...1 doc IRT Eurocard Type DVS 4040 5x1 ASI SDI Switcher Revision History Revision Date By Change Description Applicable to 0 10 09 2004 AL Original Issue S N 0404001 1 08 03 2011 AL Link 4 information u...

Page 3: ...ar layouts 11 SNMP What Is It 12 DVS 4040 SNMP Functions 14 Maintenance Storage 15 Warranty Service 15 Equipment return 15 This instruction book applies to units with serial number 0404001 Operational...

Page 4: ...where a mixture of analogue and digital signals are present The CPS 3050 local control switch panel kit converts the switcher for stand alone operation The CPS 9001 provides a 5 button remote control...

Page 5: ...HE14 dual IDC Other Temperature range 0 50 C ambient Mechanical Suitable for mounting in IRT 19 rack chassis with input output and power connections on the rear panel Finish Front panel Grey backgroun...

Page 6: ...efaults to using the switch pulses incoming on its PL 4 connector switch pulse in and also passes these on to switch pulse out on its PL 5 The default switcher sync pulse type for inputs 1 5 is the in...

Page 7: ...7 and replace with a short circuit either a solder bridge wire link or a zero ohm resistor This DC couples the output for connection to the preceding switcher expansion input Output 1 on the first swi...

Page 8: ...o ground on the relevant control input will now cause the switcher to operate in the same way as it would have if the switch on the local control panel type CPS 3050 had been depressed Pin connections...

Page 9: ...ations a 270 Mb s digital type distribution amplifier should be used CPS 3050 Local control All switchers are sold with a plain front panel with DC power LED and printed with the switcher type number...

Page 10: ...side of the SMU 4000 line up with the three sets of multipin sockets on the main PCB module Align all pins and then gently press the SMU 4000 all the way down into place If the SMU 4000 is not already...

Page 11: ...grams The following front panel and rear assembly drawings are not to scale and are intended to show connection order and approximate layout only DC DVS 40 40 N140 CP S 30 50 N140 Standard Fitted with...

Page 12: ...nformation and translates that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control...

Page 13: ...IRT modules that are SNMP compatible need a plug in SMU 4000 module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parameters s...

Page 14: ...uts 2 5 not present 14 xbcdx Inputs 2 3 and 4 present only Inputs 1 5 not present 15 abcdx Inputs 1 2 3 and 4 present only Input 5 not present 16 xxxxe Input 5 present only Inputs 1 2 3 4 not present...

Page 15: ...y on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not...

Reviews: