background image

Ti

tl

e

SCALE

SIZE

Sheet

DRAW

N

CHECKED

ENG. APP.

Rev

ision:

DO NOT

 COPY

 NOR

DISCL

O

SE TO

 ANY

TH

IR

D

 PAR

TY

W

ITH

O

U

T W

R

ITTEN

CONSENT

of
1

IR

T

 El

ect

roni

cs Pt

y

. Lt

d.

Dr

aw

ing No.

COPY

RIGHT

ART

A

RM

ON NSW

 AUST

RALI

A 2064

A3

N.T

.S.

5

DVA-

4004

805074

Dat

e

:

 1

15-O

c

t-

2007

RECLOCKING SERIAL D.A.

K.N.

1  26-04-2005

+5V

PCB 805075

SDO

SDO

Input

INV

SIG

N

AL

270

360

Input

 and Reclock

ing circuit

805074s2.

sch

J2/

R

A opt

ional power in

(used when fit

ted t

o

 F

RU-1030 fram

e)

1

2

3

4

5

6

7

8

9

10

13 
14 
15 
16 
17 
18 
19 
20 
21 
22

RL1

G

5

Y

-254P 5V

3

2

1

SW

1

INVERT

SIGNAL

2

1

R50

4K7

+5V

2

1

LD4

ye

ll

2

1

R46

560R

1

2

6


7

U9

IL207

1

2

L6

1

2

C47

10nF

1

2

C50

10nF

2

1

R51

560R

INVERT

L1R-L7R = 22nH

R1R-R7R =

 75R

1A

1B

2A

2B

3A

3B

4A

4B

5A

6A

6B

7A

7B

8A

8B

10A

10B

5B

11A

11B

12A

12B

13A

13B

14A

15A

15B

17A

17B

18A

18B

9A

9B

20A

20B

14B

21A

21B

22A

22B

23A

24B

24A

25B

26A

27A

27B

28A

23B

19A

19B

30A

30B

26B

31A

31B

32A

32B

25A

16A

16B

28B

29A

29B

P1

AC1

AC2

AC3

AC4

Po

w

e

r Su

p

p

ly

 cir

c

u

it

805074s4.

sch

MO

N

. O

/P

+5V

SIGNAL

+5V

PRESENT

2

1

R45

560R

3

1

2

LK2

1

2

C10

4u7

2

1

LD5

grn

1

2

L5

1

2

C46

10nF

3

8

RL2A

V23026

10

1

5

RL2B

+5V

270 M

b

/s

360 M

b

/s

2

1

R48

560R

2

1

R47

560R

2

1

LD3

grn

2

1

LD2

ye

ll

2

1

3

Q4

BAV70

(A4)

OUT

 5

OUT

 6

MON

OUT

 4

OUT

 3

OUT

 2

OUT

 1

SDI

SDI

O

u

tput

 circuit

805074s3.

sch

'DC'

grn

2

1

R49

560R

2

1

LD1

+5V

2

1

R44

N/

C

1

2

SK9

1

3

2

D7

BAV70

1

3

2

D8

BAV70

1

3

2

D9

BAV70

SIG

N

AL

 PRESENT

SIG

N

AL

 INV

AL

ARM

RX

TX

270 MHz

Control

 Interf

ace

805074s5.sch

+5V

+5V

3

2

1

Q5

BSS123

1

3

2

D11

BAV70

(OUT

PUT

S

)

IN

PU

T

1

2

L1R

1

2

L2R

1

2

3

J2

2

1

R2R

75R

1

2

L3R

2

1

R3R

75R

1

2

L5R

2

1

R5R

75R

1

2

L4R

2

1

R4R

75R

1

2

L7R

2

1

R7R

75R

1

2

L6R

2

1

R6R

75R

2

1

R1R

1A

1B

2A

2B

3A

3B

4A

4B

5A

6A

6B

7A

7B

8A

8B

10A

10B

5B

11A

11B

12A

12B

13A

13B

14A

15A

15B

17A

17B

18A

18B

9A

9B

20A

20B

14B

21A

21B

22A

22B

23A

24B

24A

25B

26A

27A

27B

28A

23B

19A

19B

30A

30B

26B

31A

31B

32A

32B

25A

16A

16B

28B

29A

29B

J1

DI

N64

O/P5

O/P6

O/P3

O/P4

O/P2

O/P1

3

2

1

SK8

1

3

5

7

9

P2

1

2

3

4

5

6

P3

Tx

R

x

Summary of Contents for DVA-4004

Page 1: ...Pty Ltd A B N 35 000 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA National Phone 02 9439 3744 Fax 02 9439 7439 International 61 2 9439 3744 61 2 9439 7439 Email sales irtelectronics com Web...

Page 2: ...er than S N 0509001 Operational Safety WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life Note that under certain conditions danger...

Page 3: ...transistor circuit The DVA 4004 is built in 3U extended Eurocard 220 mm x 100 mm module designed to mount in the IRT FRU 3000 and FRU 1030 family of Eurocard frames Functional Block Diagram Applicatio...

Page 4: ...0 Mb s lock selected LED green 270 360 Mb s lock selected LED yellow 360 Inverted signal LED yellow INV Power requirement Voltage 28 Vac CT 14 0 14 Vac or 16 Vdc Consumption 2 5 VA 80 mA General Tempe...

Page 5: ...signal path and the signal path to output 1 on the rear panel with this relay energised by the 5 volts supply the input and output circuits are completed to provide normal operation of the DVA 4004 Wh...

Page 6: ...me is connected to earth for safety reasons See frame manual for details Signal earth For safety reasons a connection is made between signal earth and chassis earth No attempt should be made to break...

Page 7: ...drawings are not to scale and are intended to show relative positions of connectors indicators and controls only DC 360 INV 270 SIG DVA 4004 N140 OUTPUT MON INVERT NORMAL J1 SK8 BYPASS ON POWER FAIL...

Page 8: ...extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment...

Page 9: ...4004 dva ib rev0 doc Page 9 of 9 15 10 2007 Drawing List Index Drawing Sheet Description 805074 1 DVA 4004 serial digital VDA schematic diagram...

Page 10: ...32A 32B 25A 16A 16B 28B 29A 29B P1 AC1 AC2 AC3 AC4 Power Supply circuit 805074s4 sch MON O P 5V SIGNAL 5V PRESENT 2 1 R45 560R 3 1 2 LK2 1 2 C10 4u7 2 1 LD5 grn 1 2 L5 1 2 C46 10nF 3 8 RL2A V23026 10...

Reviews: