DTR-4630 

I.R.T. Communications Pty Ltd | www.irtcommunications.com 

 

 

Page 4 of 17

 

Revision 02 

OPERATIONAL SAFETY 

 

 

WARNING 

 

Operation  of  electronic  equipment  involves  the  use  of  voltages  and  currents  that 
may  be  dangerous  to  human  life.  Note  that  under  certain  conditions  dangerous 
potentials may exist in some circuits when power controls are in the 

OFF

 position. 

Maintenance personnel should observe all safety regulations. 

 

Do  not  make  any  adjustments  inside  equipment  with  power 

ON

  unless  proper 

precautions are observed. All internal adjustments should only be made by suitably 
qualified  personnel.  All  operational  adjustments  are  available  externally  without 
the need for removing covers or use of extender cards. 

 
 
 

 
 

 

Optical Safety 

 

The  light  emitted  from  the  LASER  diode  used  in  this  system  is 
invisible  and  may  be  harmful  to  the  human  eye.  Avoid  looking 
directly  into  the  fibre  optic  cable  or  connectors  or  into  the 
collimated beam along their axis when the device is in operation. 
Operating  the  LASER  diode  outside  of  its  maximum  ratings  may 
cause device failure or a safety hazard. 

 

 
 

DANGER

 

Avoid direct exposure to beam

 

Peak power 

2 mW 

Wavelength 

1270–1610nm 

 

Class 1 LASER Product

 

Invisible LASER radiation-

 

Summary of Contents for DTR-4630

Page 1: ...DTR 4630 I R T Communications Pty Ltd www irtcommunications com Revision 02 3G HD SD SDI ASI Fibre Optic Transceiver User Manual...

Page 2: ...sion Date By Change Description Applicable to 00 06 05 2013 AL Original Issue Units fitted with firmware version Dxx463xS1V1 01 19 06 2013 AL Alarm conditions and SNMP MIB descriptors corrected Units...

Page 3: ...ation 7 User DIP switch and link settings 7 Installation 8 Signal Connections 8 Optical Connections 9 Alarm Connections 9 Front and rear layouts 10 Operation 11 Figure 1 Attenuation versus wavelength...

Page 4: ...ns are observed All internal adjustments should only be made by suitably qualified personnel All operational adjustments are available externally without the need for removing covers or use of extende...

Page 5: ...4630 can be used as an independent transmitter and receiver at the same time allowing bi directional operation over two single mode fibres Being independent from each other the transmit and receive si...

Page 6: ...to 18 dBm input level at 3G SDI typically 20 dBm at HD SD SDI Available wavelengths 1310nm or 1550nm Other wavelengths available upon request Optical path loss4 5 9 to 27 dB at 3G SDI typically 30 dB...

Page 7: ...6 OFF Enable automatic input changeover on loss of primary input IN 1 to Tx IN 1 takes priority over IN 2 ON Disable automatic input changeover SW1 7 OFF DIP switch control ON SNMP control SW1 8 OFF...

Page 8: ...default setting of the DTR 4630 is to automatically operate at either 2 97 Gb s 3G SDI 1 485 Gb s HD SDI or 270 Mb s SD SDI ASI signals and do not require any adjustment prior to use with the excepti...

Page 9: ...receiver part of the transceiver For the standard DTR 4630 with no WDM option fitted an external optical attenuator is supplied as standard with the unit For DTR 4630 s fitted with a WDM device only t...

Page 10: ...7 Revision 02 Front rear panel connector diagrams N140 CAUTION Direct connections to module DC DTR 4 6 30 OPTICAL 3G HD SD Rx Tx Separate Tx Rx Fibres Standard Tx Rx Tx Mon or Rx O P link select Rx O...

Page 11: ...of the receiver section which is used in signal presence alarm indication on detection or absence of a valid 3G HD or SD signal Single mode optical cable is directly connected to the module at the rea...

Page 12: ...inated thus the OPTICAL alarm LED is likely to be indicating that the optical signal level is low or approaching the minimum signal strength allowed before signal failure takes place whence the receiv...

Page 13: ...nformation and translates that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control...

Page 14: ...T modules that are SNMP compatible may need an optional plug in SNMP module with a program relevant to the module that it is plugged into Depending on the module besides the module identification para...

Page 15: ...ing or invalid 8 nonUrgent 2 Optical Rx input is low or cable output is muted indicating that signal is either absent or invalid 9 nonUrgent 1 2 Both nonUrgent 1 and nonUrgent 2 alarm conditions are p...

Page 16: ...abled No Traps sent on change of electrical signal presence 2 enabled Traps automatically sent on change of electrical signal presence 3 na Not Applicable opticalStatus An indication of how the SFP op...

Page 17: ...e Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be service...

Reviews: