Maintenance & storage 

 

Maintenance: 

 
No regular maintenance is required. 
 
Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind. 
This is especially important in fibre optic equipment where cleanliness of optical connections is critical to 
performance. 
 

Storage: 

If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed 
plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be 
included to deter corrosion. 
 
Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures 
should be followed when inserting or removing cards from these bags. 
 

Warranty & service

 

 
Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary 
conditions apply under a particular contract of supply. For situations when “

No Fault Found

” for repairs, a 

minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not. 
 
Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on 
components shall be extended by IRT only to the extent obtainable from the component supplier. 

 
Equipment return: 

Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment. If 
possible, confirm this by substitution. 
 
Before returning equipment contact should be made with IRT or your local agent to determine whether the 
equipment can be serviced in the field or should be returned for repair. 
 
The equipment should be properly packed for return observing antistatic procedures. 
 
The following information should accompany the unit to be returned: 
 

1.  A fault report should be included indicating the nature of the fault 
2.  The operating conditions under which the fault initially occurred. 
3.  Any additional information which may be of assistance in fault location and remedy. 
4.  A contact name and telephone and fax numbers. 
5.  Details of payment method for items not covered by warranty. 
6.  Full return address. 
7.  For situations when “

No Fault Found

” for repairs, a minimum charge of $A100.00 will apply, whether 

the equipment is within the warranty period or not. 

 
Please note that all freight charges are the responsibility of the customer. 
 
The equipment should be returned 

to the agent who originally supplied the equipment or, where this is not 

possible

, to IRT direct as follows. 

Equipment Service 
IRT Electronics Pty Ltd 
26 Hotham Parade 
ARTARMON 
N.S.W. 2064 
AUSTRALIA 
 
Phone: 

61 2 9439 3744 

Fax:  61 2 9439 7439 

Email: [email protected] 

 

IRT 

Communications 

www.irtcommunications.com

Summary of Contents for DAA-3400

Page 1: ...ternet at http www irtelectronics com I R T Electronics Pty Ltd A B N 35 000 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA National Phone 02 9439 3744 Fax 02 9439 7439 International 61 2 9439...

Page 2: ...s the use of voltages and currents that may be dangerous to human life Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position Ma...

Page 3: ...and this signal drives output line driver circuits for the nine outputs from the DAA 3400 eight to the rear panel assembly via transformers T2 T9 and one via T10 to the front panel monitor connector T...

Page 4: ...s Power requirement per unit 14V 0 14Vac 2 VA Connectors Unbalanced BNC Balanced Phoenix 3 terminal plug in screw terminal blocks Operating temperature range 0 50 C ambient Mechanical 6 HP x 3 U x 220...

Page 5: ...frame or chassis See details in separate manual for selected frame type Installation Installation requires the unit to be plugged into the front of the mounting frame and the rear assembly to be secur...

Page 6: ...ale and are intended to show connection order and approximate layout only OUTPUT MON DC DAA 3400 N140 ZAA 3401 3 2 Gnd AES O P s 75 Ohm INPUT 110 Ohm 3 2 Gnd 3 2 Gnd 3 2 Gnd 3 2 Gnd 3 2 Gnd 3 2 Gnd 3...

Page 7: ...le from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment If possible confirm this by substitution Be...

Page 8: ...Drawing Sheet Description 804169 1 DAA 3400 AES EBU distribution amplifier 804174 1 ZAA 3400 75 ohms unbalanced rear assembly 804175 2 ZAA 3401 110 ohms balanced rear assembly I R T C o m m u n i c a...

Page 9: ...7 6 5 4 3 2 1 U3 DS9638 8 7 6 5 4 3 2 1 U4 DS9638 8 7 6 5 4 3 2 1 U5 DS9638 8 7 6 5 4 3 2 1 U6 DS9638 R2 75 1 3 2 FL1 1 3 2 FL2 1 3 2 FL3 1 3 2 FL4 2 1 ZD1 1N5364 VIN 2 VIN 1 V 4 V 3 5 CONV1 ZS32405...

Reviews: