INSTALLATION

 

 

Pre-installation: 

 

Handling: 

 
This equipment may contain or be connected to static sensitive devices and proper static free handling precautions 
should be observed. 
 
Where  individual  circuit  cards  are  stored,  they  should  be  placed  in  antistatic  bags.  Proper  antistatic  procedures 
should be followed when inserting or removing cards from these bags. 
 

Power: 

 
AC mains supply:  

Ensure that operating voltage of unit and local supply voltage match and that correct rating 
fuse is installed for local supply. 

 
DC supply:  

Ensure that the correct polarity is observed and that DC supply voltage is maintained within 
the operating range specified. 

 

Earthing: 

 
The earth path is dependent on the type of frame selected. In every case particular care should be taken to ensure 
that the frame is connected to earth for safety reasons. See frame manual for details. 
 

Signal earth: 

For safety reasons a connection is made between signal earth and chassis earth. 

 

No attempt should be made to break this connection. 

 

Installation in frame or chassis: 

 
See details in separate manual for selected frame type. 
 

Signal Connections:

 

 

 

Input signal connections are made to the two removable screw terminal blocks at SK1 and SK2.  
 
The audio inputs are bridging > 30 kΩ, if a 600 Ω termination is required close LK1 and LK2 with a wire link soldered 
at the LK1 and LK2 positions on the rear panel. 
 
Output signal connections are made to connectors SK3 and SK4 on the selected  rear panel of the AAC-3390. 
 
Use rear panel ZAC-3390 for two unbalanced 75 ohms BNC output circuits or rear panel ZAC-3391 for two balanced 
100 ohms output circuits. 
 
The  reference  input  signal  can  be  either  at  SK5  a  75  ohms  unbalanced  terminating  input    or  at  SK6  a  110  ohms 
balanced terminating input, the 

input selection

 is done by links 

SW1, SW2 on the module pcb

 near pin 32 of the 

board  connector.  Move  the  links  provided  to  the  75  or  110  positions  marked  on  the  board  as  required.  The 
reference input signal will then be connected to the appropriate input connector on the rear panel.  
 
The presence of AES signal at the output of the ZAC-3390 can be monitored using the front panel monitoring BNC 
socket provided. 
 

Summary of Contents for AAC-3390

Page 1: ...AAC 3390 I R T Communications Pty Ltd www irtcommunications com Revision 04 Analogue Stereo to AES Audio Converter User Manual...

Page 2: ...n History Revision Date By Change Description Applicable to 01 01 02 2001 AL IRT border page added for PDF format S N 9911001 02 01 02 2001 AL 00COMMON doc file contents added S N 9911001 03 25 07 200...

Page 3: ...Operational Safety 4 General Description 5 Technical Specifications 6 Configuration 7 Link settings 7 Potentiometer settings 7 Installation 8 Signal Connections 8 Selection of Internal or External Cl...

Page 4: ...conditions dangerous potentials may exist in some circuits when power controls are in the OFF position Maintenance personnel should observe all safety regulations Do not make any adjustments inside eq...

Page 5: ...to a station reference The reference input can be either 110 Ohms terminating balanced line or 75 Ohms terminating unbalanced line Both connections are provided on the rear panel assembly Selection o...

Page 6: ...monitoring 1 x 75 unbalanced 1 Vp p Format AES3 1992 standard Performance Sample rate 48 kHz internal rate or as set by external reference Output signal rise and fall times 20 ns Frequency response 0...

Page 7: ...SW2 75 AES reference input 75 Ohm unbalanced BNC 110 AES reference input 110 Ohm balanced 3 pin Phoenix plug type Rear Assembly Rear assembly links LK1 and LK2 open circuit default analogue input imp...

Page 8: ...chassis earth No attempt should be made to break this connection Installation in frame or chassis See details in separate manual for selected frame type Signal Connections Input signal connections ar...

Page 9: ...rnal clock and the external clock open links LK6 and LK15 on the module main circuit board In this mode of operation the AAC 3390 will lock to a external reference applied to the external reference in...

Page 10: ...panel connector diagrams ZAC 3390 Unbalanced AES O P s Rear Assembly Option Analogue Input Left Right Unbalanced AES O P s Reference AES I P Bal Unbal Link select ZAC 3391 Balanced AES O P s Rear Ass...

Page 11: ...e Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be service...

Reviews: