irsystem PRIMAVERA NEO HK1 Operation Manuals Download Page 2

Table of contents

All of the Safety Instructions contained in this Manual must be read carefully and must be fully 
understood before you attempt to use your floor heating system, in order to avoid potential 
hazards that could cause bodily injury, property damage, or damage the floor heating system.
Store this manual near a controller, for convenient future reference.

1

Precaution

2

Thank you for purchasing PRIMAVERA.

◆ The Primavera

's specifications and designs are subject to change without notice.

◆ The material contained in this manual consists of information that is the property of 
  IRSYSTEM Co., Ltd. and is intended solely for use by the purchasers of the equipment 
  described in this manual. IRSYSTEM Co., Ltd. expressly prohibits the duplication of any 
  portion of this manual or the use thereof for any other than the operation or maintenance 
  of the equipment described in this manual without the express written permission of 
  IRSYSTEM Co., Ltd.

Precaution ------------------------------------------------------------------------

Preparation (1) ---------------------------------------------------------------------- 
   (Names of parts and their Functions)
   (LCD Panel)

Preparation (2) ----------------------------------------------------------------------
   (Setting current time)

System Operation --------------------------------------------------------------------
   (Performing of “Normal operating” )
   (Changing temperature level)
   (Child-Lock function)
   (Automatic Cut-Off function)

Advanced Operations 1 ------------------------------------------------------------- 
   ( “On-Off” Time Setting)

Advanced Operations 2 -------------------------------------------------------------
   ( “Operating Term Setting” )

Advanced Operations 3 ---------------------------------------------------------------
   ( “Starting Time Setting” )

TROUBLE SHOOTING ----------------------------------------------------------------

FAQ ------------------------------------------------------------------------------

Specifications -------------------------------------------------------------------

3

5

6

8

11

12

13

15

17

Warning!!!

It could cause fire, electric shock or mechanical troubles.

Follow these safety regulations below to prevent 

serious injury

 or 

death

.

◆ 

Do not disassemble, modify or repair PRIMAVERA. 

It could cause fire, electric shock or mechanical troubles.

◆ 

Do not spill any liquid on/near PRIMAVERA heating area or controllers.

It could cause fire, electric shock or mechanical troubles.

◆ 

Do not damage PRIMAVERA heating area or controllers on any foreign 

  

sharp objects such as nails or cutter knifes.

It could cause fire or mechanical troubles.

◆ 

Never leave any other strongly flammable objects such as spray cans or 

     lighters on/near PRIMAVERA heating area.

Caution!!!

Follow these safety regulations below to prevent 

serious injury

death

 and 

material damage

.

It could cause mechanical troubles or malfunction.

◆ 

Avoid using PRIMAVERA under the certain conditions like a direct sunlight, 

     a high temperature, high humidity, dust, inflammable gas, corrosive gas, 

     strong vibration, shocking strike.

It could cause fire or electric shock by short-circuit.

◆ 

Never try to clean controller's surface with water, alcohol or any other 

  

chemicals.

◎ 

Avoid lying down onto the floor heating system directly for a long time without 

 

attention. It could cause a skin irritation, such as a skin burn.In particular, 

     the special attention is required when the following people operate PRIMAVERA.

● People who are not able to change their position by themselves on PRIMAVERA, or be impossible 

    to control temperature level by own will; infants, babies, children, the disabled or the elderly.

● People who have delicate skin type.

◎ 

Be careful of the overheating.

Do not place high insulating materials (thick carpet) or furniture (which has no legs) onto PRIMAVERA 
directly; otherwise it could happen troubles due to overheating between PRIMAVERA and high 
insulation materials. Placing furniture having with at least 5cm legs onto PRIMAVERA would be no 

problems.

Refer to FAQ section (P.15 - P.16) for preventing accident.

Summary of Contents for PRIMAVERA NEO HK1

Page 1: ...Co Ltd Tokyo branch Add 1 2 3 3F IRIYA TAITO KU TOKYO JAPAN 110 0013 Tel 81 3 6802 4846 Fax 81 3 6802 4847 Head Office Add 1 14 33 6F ESAKACHO SUITA CITY OSAKA JAPAN 564 0063 Tel 81 6 6310 6826 Fax 81 6 6310 6827 http www irsystem jp e mail osaka irsystem jp Manufacturing and sales by ...

Page 2: ... could cause fire electric shock or mechanical troubles Do not spill any liquid on near PRIMAVERA heating area or controllers It could cause fire electric shock or mechanical troubles Do not damage PRIMAVERA heating area or controllers on any foreign sharp objects such as nails or cutter knifes It could cause fire or mechanical troubles Never leave any other strongly flammable objects such as spra...

Page 3: ...tion display Error display Operating indicator Error code display Programmed time indicator 24 hour time display Temperature level indicator Child Lock display Heating zone indicator Function display Display contents Description Error display Displays the current operating status Operating indicator Displays when abnormal operating occurs Displays when Child Lock function is on Heating zone indica...

Page 4: ...Press ON OFF button Heating zone 2 HK1 controller setting HK2 controller setting Not operated Normal Operating Press in order to switch the power on to off Not operated Normal Operating Heating zone 1 Press in order to switch the power on to off Heating zone 2 Press in order to switch the power on to off Changing temperature level Press while the system is running Using adjust the comfortable temp...

Page 5: ...wants to change setting condition even though it is on Child Lock function press buttons for few seconds Automatic Cut Off function The system operating will stop automatically after 8 hours working therefore the user cannot set On Off Time Setting over 8 hours On Off Time Setting Primavera is possible to set two operating time programs for each day During ON OFF Time Setting is running the system...

Page 6: ...utton Adjust the temperature level Using adjust the comfortable Press Fix the temperature level setting ond 1 temperature level Setting procedure On time of Program 2 Press while On Off Time Setting is running The number On time displays flashing Using adjust time at 18 00 Press Fix On time setting on 2 Setting procedure Off time of Program 2 The number Off time displays flashing Using adjust time...

Page 7: ... after completed setting of heating zone 1 Repeat the same procedure Press Setup button few seconds Return to the status of the Programming Operating Term Operating Term Setting would be saved if the user press Operating term is limited on 120 minutes This function cannot be used in while ON OFF Time Setting is running Starting Time Setting This function allows reserving the Starting Time while th...

Page 8: ...function and LCD panel is displayed oFF mark at that time On Off time setting could not be programmed Didn t you attempt to set On Off time more than 8 hours Operating time is limited until 8 hours at once Set operating time within 8 hours When symptoms are not improved by the above methods turn off The circuit breaker immediately and please contact to IRSYSTEM Co Ltd F1 signifies the heating zone...

Page 9: ...ch is very valid for human body Q Is it safe to drop water onto the floor heating system A PRIMAVERA is made of waterproof structure basically There is no problem even if it drops small amount of water However if it is spilled large amount of water onto the floor heating and neglect it for a long time it could cause an accident possibly resulting in mechanical troubles Do not spill any liquid onto...

Page 10: ...Operating term 1 to 120 min Starting Time setting Function of protecting overuse W116mm H120mm D50 4mm 270g Installation standard Terminals Installation circumstance Protection functions Others HK2 Control two heating zones AC 200V 12A load resistance 2 A Switch box of JIS2 standard All opening of installation position Vertical installation Non screw terminal board 10 40 45 85 RH non condensation ...

Reviews: