background image

operating system. Refer to the software instructions below for information on using
WaterGraph software to retrieve data from the card.

Maintenance

The 

Data Shuttle enclosure is not designed to protect the device from moisture

or excessive dust. Keep the 

Data Shuttle in the supplied storage pouch or a clean

and dry environment to ensure long life.

When battery replacement is necessary, remove the snap cover from the back of

the 

Data Shuttle by firmly pressing in and down. Remove the old battery and replace

with a new 9V battery.

Troubleshooting:

Immediate audible beep and red LED when pressing the green button:

This indicates a problem with the card. Check to see if the card is inserted or
inserted upside down.

Long green LED followed by red LED and audible beep:

This indicates a failure to connect to the Monitor. Check the cable connection
between the 

Data Shuttle and Monitor. Verify that the Monitor is functioning

by pressing the green button and viewing the display.

Orange LED:

Battery is low and should be replaced.

LED always red:

Battery is too low to operate and should be replaced.

Software Instructions

WaterGraph versions 3.2 (for 900M) or 4.1 (for 950R) are required for importing

Data Shuttle data. The installation programs for both are included on the multimedia
card (MMC) supplied with your 

Data Shuttle. To install the program, browse to the

drive assigned to the card and launch the Setup_3.2.exe or Setup_4.1.exe file.

Importing Data

Remove the card from the 

Data Shuttle and insert it in to the PC card reader. The

PC should recognize the card and prompt the user. Note the drive letter assigned to
the card by the PC and cancel out of the prompt.