![IROX Mete-On 3 Instructions For Use Manual Download Page 12](http://html.mh-extra.com/html/irox/mete-on-3/mete-on-3_instructions-for-use-manual_2091789012.webp)
12
- Weak batteries that need to be changed can be detected by a weakening contrast in the LCD. Increasing
problems in data reception can also be caused by weak batteries. Consequently, please replace batter-
ies with diffi cult-to-read displays like this immediately.
- All data and settings are lost when the battery is changed.
9.
More information about the ‘METEOTIME’ device
More info about the system can be found on the Internet at
www.meteotime.com
ERROR
• incorrect time and
date in the display
• the Meteotime symbol in
the status area is not
fully displayed
• there are gaps in the
weather forecasts or
they are not available
• the rings on the
radio tower
are missing
• the contrast in the display
is becoming weaker
or is poor.
• the forecast pictogram is
constantly alternating, in
the temperature forecast
there are only dashes.
Nevertheless, the
Meteotime symbol is
fully on
CORRECTION
The place of installation of the Mete-On 3 is
unsuitable.
Find a place of installation where there is no
interference to the radio reception.
Use the ‚TEST‘ function from the
instructions for use.
There is electrical interference at the place of
installation of the Mete-On 3 or the reception is
too weak.
Use the ‚TEST‘ function from the instructions for
use to fi nd a more favourable place of installation
or to remove the interfering device.
As the interference may occur at night, please look
for another place as a precautionary measure.
It may be suffi cient to turn the device 30-90°.
There is interference to the reception at the place
of installation of the Mete-On 3.
Use the ‚TEST‘ function from the instructions for
use to fi nd a more favourable place of installation.
Replace the batteries.
(2 x LR6 AA battery - alkaline or lithium)
This interference to reception may be temporary;
if it occurs often, a more favourable place of
installation should be sought.
No data have yet been received.
Wait until the morning (see Chapter 2)
CAUSE
The radio reception of
Mete-On 3 has been
disrupted.
There was interference
to the radio reception
of Mete-On 3in the
night and less than
75% ofthe data recei-
ved are correct.
It has not been possi-
ble to update the time
during the previous 12
hours.
The batteries have
been used up.
In normal operation:
It has not been possi-
ble to receive the
respective weather
data for 2 days.
After the system is put
into operation for the
fi rst time or after a
change in batteries.
10.
Possible faults, their causes and their correction
12