background image

98

99

97

96

8e) ALARM FEATURE

* Weekday Alarm

The alarm sound will be activated and the icon will be 

flashed on weekday when it is armed and the alarm time 

is reach.

* Single Alarm

The alarm sound will be activated and the icon will be

flashed once when it is armed and the alarm time is 

reach. Once it finished, it will be disabled automatically.

* Pre-Alarm

The pre-alarm sound will be activated and the icon 

will be flashed if outdoor temperature under or equal 

two degree C.  Which is programmable 15, 30, 45, 60 or 

90 minutes earlier than the weekday alarm or single 

alarm time.

PRECAUTIONS

This product is engineered to give you years of 

satisfactory service if you handle it carefully. Here are 

a few precautions:

1. Do not immerse the unit in water.

2. Do not clean the unit with abrasive or corrosive 

materials. They may scratch the plastic parts and 

corrode the electronic circuit.

3. Do not subject the unit to excessive force, shock, dust,

temperature or humidity, which may result in 

malfunction, shorter electronic life span, damaged 

battery and distorted parts.

4. Do not tamper with the unit's internal components. 

Doing so will invalidate the warranty on the unit and 

may causeunnecessary damage. The unit contains no 

user-serviceable parts.

5. Only use fresh batteries as specified in the user's 

manual. Do not mix new and old batteries as the old 

ones may leak.

6. Always read the user's manual thoroughly before 

operating the unit.

9. SPECIFICATIONS

Temperature Measurement

Main unit

Indoor Temperature measurement

Proposed operating range 

:  0

°

C to +50.0

°

C

32.0

°

F to 122.0

°

F

Humidity Measuring range

: R.H. 10% to 95%

at 25˚C ( 77˚F )

Temperature resolution 

:  0.1

°

C

0.2

°

F

Humidity resolution

: 1% R.H.

Barometric Pressure Measurement

Pressure measuring range

: 750 to 1100 mb/hPa 

at 25

°

C

(22.15 to 32.49 inHg)

Pressure sampling cycle

: 20 minutes

Moon Phase Functions

Moon Phase Scanner Range

: forward/

backward 39 days

Remote unit

Proposed operating range 

:  -20

°

C to + 60

°

C

-4 

°

F to 140 

°

F

Temperature resolution 

:  0.1

°

C

0.2

°

F

RF Transmission Frequency 

: 433 MHz

Maximum No. of Remote unit

: 3

RF Transmission Range 

: Maximum 30 meters

(open area)

Temperature sensing cycle 

: around 43~47 seconds

Relative Humidity Measurement

Remote relative humidity

: 10%RH to 95%RH

measurement range

Resolution

: 1%RH

UV sensor

Proposed operating range

: 0.0UVI to 16.0UVI

: 0.0 MED/h to 

6.9 MED/h

Resolution

: 0.1UVI / 0.1 MED/h

RF Transmission  Frequency

: 433 MHz

Max. No. of remote unit

: 1

RF Transmission Range

: Maximum 30 meters

: (open area)

UV sensing cycle

: 5 minutes

Power

Main unit 

: use 2 pcs UM-3 or 

“AA” 1.5V battery

Remote sensing unit 

: use 2 pcs UM-3 or 

“AA” 1.5V battery

Weight

Main unit 

: 335g (without battery)

Remote sensing unit

: 62g (without battery)

Remote UV sensor

: 78g (without battery)

Dimension

Main unit 

: 220 x 90 x 33 mm

Remote sensing unit 

: 55.5 x 101 x 24 mm

                           

          CAUTION

-  The content of this manual is subject to change 

without further notice.

-  Due to printing limitation, the displays shown in 

this manual may differ from the actual display.

-  The contents of this manual may not be reproduced

without the permission of the manufacturer.

0125

EC-DECLARATION OF CONFORMITY

  Product : TE761EL / HBVR761

      

This product contains the approved transmitter and 

complies with the essential requirements of Article 3 of 

the R&TTE 1999/5/EC Directives, if used for its 

intended use and that the following standard(s) has/have 

been applied:

Efficient use of radio frequency spectrum

(Article 3.2 of the R&TTE Directive)

applied standard(s)                              

EN 300 220-1,3:2000

Electromagnetic compatibility

(Article 3.1.b of the R&TTE Directive)

applied standard(s)                              

EN 301 489-1,3:2000

applied standard(s)                              

EN 300 339:2000

Additional information:

The product is therefore conform with the Low Voltage

Directive 73/23/EC, the EMC Directive 89/336/EC and

R&TTE Directive 1999/5/EC (appendix II) and carries

the respective CE marking.

RTTE Compliant Countries :

All EU countries, Switzerland   

CH

QA MANAGER :   H.Y.WANG
K.S plastic factory
Guan Lan / Shen Shen / China

Summary of Contents for HBVR761 UV-X

Page 1: ...vel It also retains the maximum and minimum relative humidity readings A remote thermo hygro and a UV sensor are included with the unit is able to receive and display readings from up to 3 remote thermo hygro sensors and from 1 UV sensor The built in barometer enables to display the atmospheric pressure with user selectable altitude adjustment A bar graph will show the pressure trend of the last 2...

Page 2: ...GHT BUTTON Activate the snooze function and backlight O WALL MOUNT RECESSED HOLE For mounting the main unit on a wall P BATTERY COMPARTMENTS Accommodates two UM 3 or AA size 1 5V batteries Q REMOVABLE TABLE STAND For standing the main unit on a flat surface MAIN FEATURES THERMO HYGRO REMOTE UNIT A LED INDICATOR Flashes once when the remote unit transmits a reading Flashes twice when low battery is...

Page 3: ...rk The default unit of pressure is hPa mBar unit of height is meter height is 10 meters It will use the default value if no key is pressure for 60 seconds Thereafter the setting of the altitude in meters can only be done after reinserting the batteries SETTING UP THE REMOTE SENSORS a Once batteries are in place for the remote unit they will start transmitting temperature and humidity and UV readin...

Page 4: ...sure applies Use PRESSURE ALTITUDE key to toggle the display to sea level pressure display Press and hold the Pressure Altitude key to enter the sea level pressure adjusting mode Use the or rear panel key to enter sea level pressure and use PRESSURE ALTITUDE to confirm 5 THERMOMETER HUMIDITY 5a HOW TO CHECK REMOTE AND INDOOR TEMPERATURES The wave display on the outdoors temperature indicates the r...

Page 5: ...ied 6 MOON PHASE 6a HOW TO USE AND SCAN THE MOON PHASE HBVR761 is equipped with a moon phase display and scanner with which eight moon phases are displayed on the screen from new moon to waning crescent The one falls on the current day will flash on the screen If it is a full moon or new moon day the icon will flash faster The eight phases are To check the moon phase for a particular day press the...

Page 6: ...orward backward 39 days Remote unit Proposed operating range 20 C to 60 C 4 F to 140 F Temperature resolution 0 1 C 0 2 F RF Transmission Frequency 433 MHz Maximum No of Remote unit 3 RF Transmission Range Maximum 30 meters open area Temperature sensing cycle around 43 47 seconds Relative Humidity Measurement Remote relative humidity 10 RH to 95 RH measurement range Resolution 1 RH UV sensor Propo...

Reviews: