background image

25

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900205-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

IronStrike™ Brand Wood Burning Stove and Insert

Limited Lifetime Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your IronStrike™ Brand Wood Burning Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime 

Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 

Limited Lifetime Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If 

repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will 

also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS 

AND LIMITATIONS to this Limited Lifetime Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this Limited Lifetime Warranty. The following do not carry a Limited Lifetime Warranty but are warranted as follows:

Cast Iron Heat Exchanger

 – Replacement for five years from the date of installation

Cast iron parts

 – Replacement for one year from the date of installation

Catalyst 

– Carries a separate warranty. Refer to the warranty certificate provided for that part

Electrical components

 – Repair or replacement for one year from date of installation

Gaskets

 – Replacement for one year from the date of installation.

Gold & nickel plating

 – Replacement for two years from date of installation. Excludes tarnishing

Refractory & screens

 – Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes

 – Repair or replacement for seven years from date of installation. IHP prevailing labor rates for years one through five.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component, unless otherwise noted

Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood 

products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly; IHP stoves, inserts and high 

efficiency EPA fireplaces are approved for burning dry seasoned wood only.); (c) damages caused by failing to provide proper maintenance and service in accordance with 

the instructions provided with the Product; (d) damages, repairs or  inefficiency resulting from faulty installation or application of the Product.
Coverage of this Limited Lifetime Warranty is conditional upon the appliance being operated without the use of grates, irons or any other method to elevate the fire.
IHP is not responsible for inadequate system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions 

which may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inad-

equate chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with 

Security Chimneys International, Ltd. chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due 

to any malfunction or defect in equipment are not covered by this Limited Lifetime Warranty. All replacement or repair components will be shipped F.O.B. from the nearest 

stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a 

particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed 

warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 

Lifetime Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ 

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.IRONSTRIKE.US.COM.

Summary of Contents for Striker C160

Page 1: ...éro de la pièce 900100 00 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before installing and using your wood fireplace insert Failure to followtheseinstructionscouldresultinpropertydamage bodilyinjury orevendeath Contactyourlocalbuildingorfireofficialstoobtain a permit and inform...

Page 2: ...arth Protection 8 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provided in this manual PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE Chimney Requirements 9 Installation Procedure Masonry Chimney 9 Positive Flue Connection 10 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fire...

Page 3: ...heburn ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a hot fire If large ac cumulationsareoccurring reviewyourburningprocedures 14 Ifacreosotefireshoulddevelop thefiredepartmentshould be called immediately and then attempts should be made to cont...

Page 4: ...ay include Cracking warping or burning out of components plated accessories may turn color stove glass may develop a haze which will not come off with cleaning Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached beyond the design capabilities of the appli ance The damage that occurs from overfiring is not covered under the manufacturer s limited warran...

Page 5: ...heater In well insulated and weather tight homes it may be difficult to establish a good draft up the chimney caused by a shortage of air in the home The lack of air is caused by many common household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Also the combustion process of this heat...

Page 6: ... The final step of the baffle board baffle blanket installation will be installing the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffle boards of the four baffle board kit They will be installed with the 7 3 8 dimension from the front to rear of the firebox Start by setting the back side of the board on the rear baffle making sure ...

Page 7: ...to the side 8 200mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector This appliance may be installed in a bedroom in the United States Model A B C D E 1 C A160 USA 24 CAN 660mm USA 15 CAN 450mm 20 508mm 12 305mm USA 4 1 2 CAN 200mm C A160 with mantel and or side shields 16 406mm...

Page 8: ...ken from Tables 2 and 3 Using the k formula FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 84 TM inches 35 x 375 84 156 inches 417 x 375 Answer TheminimumrequiredthicknessoftheMicore1...

Page 9: ...are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround panels and level the fireplace insert with the leveling bolts using a 3 4 19 mm socket extensions to reach the bolt head and a ratchet 8 Glue the insulation around the outer edge of both the top and side surroun...

Page 10: ...l off plate i e 22 gage sheet steel in the fireplace throat using masonry screws Other acceptable methods include packing noncombustible material i e high temp fiberglass or ceramic insulation around the vent pipe or using a flue adapter Whatever seal off method is used it must effectively seal the area to prevent room air passage to the chimney cavity of the fireplace Offset Boxes Offsets can be ...

Page 11: ...3 76 mm long bolts with the head up through the nuts attached to the insert on the lower rear corner of each side This will allow you to level the insert when placed into the fireplace Measure from the front of the top surround mount to the center of the flue Determine if there is an alignment problem in connecting a liner from the chimney to the insert s flue If there is an alignment problem conn...

Page 12: ...UR INSURANCE COMPANY Chimney Liner Installation Place the insert into the fireplace making sure to center it side to side Slide the insert in until the surround mounts are approximately 1 2 13 mm from the face of the fireplace where the surround panels cover Lower the chimney and make attachment to the insert Level the fireplace insert by using a 3 4 socket and a long extension and adjusting the b...

Page 13: ...ed while the front door is slightly open Once kindling is burning well larger pieces of wood may be added then the door should be fully closed if there was the need to keep it slightly open during start up DO NOT LEAVE THE APPLIANCE UNATTENDED WHILE THE FRONT DOOR IS SLIGHTLY OPEN CAUTION Do Not alter the adjustment range of the draft control for increased firing for any reason Operate only with f...

Page 14: ...clockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch TWO S MANUAL WHT NOTE SWITCH CONDITIONS GIVEN AT ROOM TEMPERATURE N C NORMALLY CLOSED N O NORMALLY OPEN FEMALE DISCONNECT MALE DISCONNECT STUD CONNECTION TWO POSITION SWITCH MANUAL TEMPERATURE AUTO RES TEMPERATU SWITCH N POWER CORD RED RED YLW BLK WHT GRN NOTE SWITCH CONDITIONS GIVEN AT ROOM TEMPERATURE N C ...

Page 15: ... down to 275 to 400 degrees on Elite inserts locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few minutes to ignite the wood All IHP stoves and fireplace inserts are EPA tested for emissions at low burn with the air control completely closed Whether or no...

Page 16: ...e E clip from the upper hinge pin Remove upper hinge pin by pulling up while holding the op posite side of the door Lift door out of the lower hinge pin and place face down on a soft surface Step 2 Remove Door Back Screws 6 ea Using a 5 32 allen wrench remove the 6 retainer screws from the faceplate To locate screws peel back the door gasket as necessary Step 3 Disassemble Door Assembly Flip door ...

Page 17: ...ve and Clean Glass above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote See Creosote section on Page 5 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed fur...

Page 18: ... the baffle assembly DO NOT Close the door tightly during Burn In period DO Be sure to clean any fingerprints from optional accessories that have plated surfaces before burning the appliance Clean the plated surfaces only with household type glass cleaner and a very soft cloth DO Consult local building department if other than recommended clearances are desired DO Read instructions for the baffle ...

Page 19: ...placement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Screws 32 H8066 Control Switch Manual Off Automatic C160 AND SWI160 INSERT PARTS 33 71138 Small Flange Screw Black S...

Page 20: ...20 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts ModelS C160 and CA160 ...

Page 21: ...21 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 Replacement Parts ModelS C160 and CA160 Door Parts Blower Parts ...

Page 22: ...3 4 x 40 71079 WFT2948 N Nickel 30 3 4 x 48 BLOWERS Cat No Model Description H7907 WSINS BLWR B SS Blower Insert Black H7908 WSINS BLWR G SS Blower Insert Gold H7909 WSINS BLWR N SS Blower Insert Nickle H7910 WSINS BLWR BN SS Blower Insert Brushed Nickel H7911 WSINS BLWR BG SS Blower Insert Brushed Gold ETCHED GLASS 71073 Glass Arch Sailboat Arch Sailboat 71069 Glass Arch Cattail Arch Cattail 7107...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL ModelS C160 and CA160 2013 2014 2015 Innovative Hearth Products LLC 1508 Elm Hill Pike Suite 108 Nashville TN 37210 ...

Page 24: ...24 NOTES ...

Page 25: ...g a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting f...

Page 26: ...ance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this system please contact your dealer Innovative Hearth Products LLC IHP 1508 Elm Hill Pike Suite 108 Nashville TN 37210 www IronStrike us com Pro...