background image

INSTALLATION AND OPERATION MANUAL

     

WARNING

 

Hot! Do not touch!  The glass and surfaces of this appliance will 

be hot during operation and will retain heat for a while after 

shutting off the appliance.   Severe burns may result. 

• 

 

Carefully supervise children in the same room as appliance.

Save These Instructions 

For Future Reference

Wood Stoves

Model Legacy™ S260 T-Top

Free-Standing 

EPA Certified

Wood-Burning Stoves

P/N 900130-00, REV. NC, 12/2013

A French manual is available upon request. Order P/N 900131-00.

Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de 

la pièce 900131-00.

This appliance must be properly installed and operated in order to prevent the 

possibility of a house fire. Please read this entire installation and operation 

manual before installing and using your wood stove. Failure to follow 

these instructions could result in property damage, bodily injury or 

even death. Contact your local building or fire officials to obtain 

a permit and information on any installation requirements 

and inspection requirements in your area.

US

Portland

Report # 050-S-02b-2

P900130-00

12

/16

/20

13

Summary of Contents for Legacy S260 T-Top

Page 1: ...h manual is available upon request Order P N 900131 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi ce 900131 00 This appliance must be properly i...

Page 2: ...em 4 Negative Pressure Warning 5 Creosote 5 Disposal of Ashes 5 Fuel 5 Burn In Period 5 Paint Curing 5 Clearances to Combustibles 6 7 Floor Protection 6 7 Reduced Clearances 6 Alcove Clearances 6 Chim...

Page 3: ...g the burn ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswith...

Page 4: ...e too restrictive see Chimney Guide lines Inadequate draft will cause the appliance to leak smoke into the room through the stove and the chimney connector joints Excessive draft may cause an uncontro...

Page 5: ...should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally disper...

Page 6: ...ons utilizing a 8 to 6 reducer cat 71134 at the flue collar If the venting system is all vertical and the total vent length above the flue outlet exceeds 14 feet it is recommended that the 8 to 6 pipe...

Page 7: ...28 711mm 18 450mm 8 200mm 13 330mm 23 584mm USA 37 1 4 CAN 1200mm 8 Double Wall Residential or Mobile Home 16 406mm 13 1 2 343mm 25 635mm 15 381mm 8 200mm 12 305mm 22 559mm USA 37 1 4 CAN 1200mm 8 Do...

Page 8: ...r Figure 5 Typical Installation Figure 6 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must...

Page 9: ...ermination All mobile home installa tions require an outside air kit see Page 27 for ordering information and the stove must be secured to the floor and grounded to the mobile home chassis Install Out...

Page 10: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimn...

Page 11: ...all cartons if any and remove the contents upon receipt and check for any damaged or missing parts If there is hidden damage notify your freight company or IHP dealer immediately CAUTION Wear gloves...

Page 12: ...rew in that leg as well 9 Install bricks and baffle as per instructions on Page 15 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blanket can...

Page 13: ...th The hole s center should be 3 76 mm directly forward from the center of the flue outlet or locate as per the instructions below 6 Position the stove on your floor protection in the exact location w...

Page 14: ...tside air vent has been sealed properly to keep rodents out if applicable 5 Be sure all roof flashings are watertight 6 Be sure the stove is properly grounded if applicable FOR YOUR OWN PROTECTION AND...

Page 15: ...stalling the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffle boards of the four baffle board kit They will be installed with the 9 5...

Page 16: ...re not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor the temperature every 15 m...

Page 17: ...ensure uninterrupted blower operation For example a small fire may require a slower blower speed to keep the heat output by the blower consistent If the blower is operated in manual mode it may be ne...

Page 18: ...top cool down to 275 to 400 degrees on Elites locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the sto...

Page 19: ...up while holding the op posite side of the door Lift door out of the lower hinge pin and place face down on a soft surface Step 2 Remove Door Back Screws 6 ea Using a 5 32 allen wrench remove the 6 r...

Page 20: ...Glass on Page 19 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front o...

Page 21: ...ffle assembly DO NOT Close the door tightly during Burn In Period DO Be sure to clean any fingerprints from optional accessories that have plated surfaces before burning the appliance Clean the plated...

Page 22: ...enum Box FSB BLOWER PARTS Item Cat No Description 25 H8062 FSB700 Blower Only Assembly w blower wiring harness 26 H5658 Fan Blade FSB700 27 H5657 Fan Cage FSB700 28 H8063 FSB700 Blower Only Wire Harne...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model S260...

Page 24: ...24 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Door Parts Blower Parts 25 29 31 28 27 26 32 30 Replacement Parts Model S260 7 11 10 6 9 5 4 4 1 8 2 3...

Page 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model S260 22 24 18 20 21 23 Leg and Leg Parts...

Page 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model S260 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal...

Page 27: ...AMEPLATE F1870 TRAD FPK BG LG Large Traditional Faceplate Kit Brushed Gold F1869 TRAD FPK G LG Large Traditional Faceplate Kit Gold BLOWER H7917 BLWR FSB700 SS Blower Kit FS Woodstoves OUTSIDE AIR KIT...

Page 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL eNGLISH 2013 2014 2015 Innovative Hearth Products LLC 1502 14th St NW Auburn WA USA 98001...

Page 29: ...29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL FRENCH Innovative Hearth Products LLC 1502 14th St NW Auburn WA USA 98001...

Page 30: ...30 NOTES...

Page 31: ...a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning d...

Page 32: ...ways give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation...