![Ironman4x4 FRIDGE40 User Manual Download Page 5](http://html1.mh-extra.com/html/ironman4x4/fridge40/fridge40_user-manual_2091435005.webp)
5
Connection
Power:
The 12/ 24V and mains power can be present at the same time, the device will always
set itself to the mains power supply as a priority.
Unit must always be connected to an adequate power supply and DC connection must always
be fused.
For cable length and specification, refer to table below.
Cable Area
12V Max Cable Length
24V Max Cable Length
[mm2]
AWG
[m]
[ft.]
[m]
[ft.]
2.5
12
< 2.5
< 8
< 5
< 16
4
12
< 4
< 13
< 8
< 26
6
10
< 6
< 20
< 12
< 39
10
8
< 10
< 33
< 20
< 66
(AWG - American Wire Gauge)
The length measurement in the above table is from the battery to the refrigerator.
Protection:
This unit has an in built automatic low-voltage cutout system, designed to protect
your battery from discharging completely. This will automatically turn off the compressor when
the battery discharges to Cut-Out voltage (See table below). The compressor will automatically
restart when voltage increases to Cut-In (See table below).
IMPORTANT:
If your fridge cuts out prematurely, this may be due to the Battery Protection being
set too high. Consider lowering the battery protection level via the switch located
on the rear power panel.
Battery
Protection
12V Cut-Out
12V Cut-In
24V Cut-Out
24V Cut-In
LOW
10.2V
11.2V
21.6V
23.0V
MED
10.7V
11.7V
22.6V
24.0V
HIGH
11.7V
12.7V
24.6V
26.0V