3. READER OPERATION

4. SPECIFICATIONS

5.

When a token is brought into reader working zone, its serial number is acquired. It is then
transmitted into controller using iButton (Dallas Touch Memory) protocol.
When reading the token serial number, the buzzer is sounding. To disable the buzzer, remove
the jumper on the reader PCB. (See Figure 1)

Working frequency: ..........................................................................................125 kHz.
Supported token type: .................................................................................EM-Marine.
Reading distance: ............................................................................................2

8 cm.

Output protocol: ................................................................................................. iButton.
Max. line distance from the controller: ....................................................................15 m.
Reading indication: .................................................................................audial buzzer.
Quiet reading function: .....................................................................................Present.
Power voltage: .................................................................................................12 V DC.
Maximum standby current: .................................................................................. 30 mA.
Casing material: ..........................................................................................ABS plastic.
Dimensions, mm: ........................................................................................65 x 65 x 20.
Weight: ..................................................................................................................40 g.

OPERATIONAL CONDITIONS

Recommended air temperature: -30

40°C.

Humidity:

80% at 25°C.

If operational conditions are differing from described above, device specifications can
deviate from specified values.
The controller is to be operated in absence of: precipitation, direct sunlight, sand, dust,
water condensation.

CP-Z

www.ironlogic.me

Figure 2.

Device dimensions.

47 mm

65 mm

20 mm

Z-5R

GND

DATA0

Reader

TM

Figure 3.

Connecting reader via

.

UTP cable CAT5e

65mm