Page 1–12
IronHorse® General Purpose AC Motors User Manual – 10th Ed. Rev A – 01/06/2021
Chapter 1: Getting Started
MtcP2 P
reMiuM
-e
fficiency
c
ast
-i
rOn
t
hree
-P
hase
M
OtOrs
f
eatures
and
s
PecificatiOns
(
cOntinued
)
s
PecificatiOns
– c
ast
-i
rOn
t-
fraMe
and
tc-
fraMe
M
OtOr
– 60h
z
/ 1800
rPM
(50h
z
/ 1500
rPM
)
***** Table Continued From Previous Page (for 1–7.5hp motors) *****
Motor Specifications
Premium-Efficiency T & TC Frame Three-Phase Motors
60Hz / 1800 rpm (50Hz / 1500 rpm)
Part Number
HP
(2)
NEMA
Fr
ame
Volt
age @
60Hz (50Hz)
Housing
Shaf
t Mat
er
ial
Conduit Bo
x
Location
(1)
Holes / Foot
Ser
vic
e F
act
or
(4)
(@50Hz)
F.L. Amps @
208-230V/460V
Pr
oduct W
eight
(lb)
MTCP2-010-3BD18
10
215T
208-230/460 – 3-phase
(200/400 – 3-phase)
TEFC cast ir
on
1045 carbon st
eel
F1
(F2)
4
1�25
(1�0)
26�9-24�3 / 12�2
193
MTCP2-010-3BD18C
215TC
MTCP2-015-3BD18
15
254T
2
40�0-36�2 / 18�1
265
MTCP2-015-3BD18C
254TC
MTCP2-020-3BD18
20
256T
4
52�4-47�4 / 23�7
304
MTCP2-020-3BD18C
256TC
MTCP2-025-3BD18
25
284T
2
65�1-58�8 / 29�4
385
MTCP2-025-3BD18C
284TC
MTCP2-030-3BD18
30
286T
4
78�1-70�6 / 35�3
430
MTCP2-030-3BD18C
286TC
MTCP2-040-3BD18
40
324T
2
104-93�7 / 46�8
531
MTCP2-050-3BD18
(2)
50
326T
4
127-115 / 57�6
578
MTCP2-060-3BD18
(2)
60
364T
F1
2
158-142 / 71�2
769
MTCP2-075-3BD18
(2)
75
365T
4
196-177 / 88�7
858
MTCP2-100-3BD18
(2)
100
405T
4
252-228 / 114
1131
MTCP2-125-3BD18
(2)
125
444T
F1
(F2)
2
323-292 / 146
1429
MTCP2-150-3BD18
(2)
150
445T
4
386-349 / 175
1625
MTCP2-200-3BD18
(2)
200
445/7T
4
506-458 / 229
2033
MTCP2-250-3D18
(2)
250
449T
460V
4140 carbon
st
eel
F1
2
1�15
280
(3)
2508
MTCP2-300-3D18
(2)
300
449T
2
336
(3)
2728
1) F1(F2) indicates F1 conduit box mounting location, field convertible to F2
(as shown on dimensional diagram).
2) For warranty on motors 50 hp and above, motors must be inspected by an EASA motor repair or
service center. See AutomationDirect Terms & Conditions for details.
3) F.L. Amps @460V only.
4) The service factor changes from 1.25 to 1.0 under the following conditions:
• When running the motor at 208VAC @ 60Hz
• When running the motor at 200/400VAC @ 50Hz
• When used with a VFD