5.3. Configuration via RS-485 Link
Configuration via an RS-485 link requires
R
eader
Conf
ig
software (see www.ironlogic.
me
website) and Z-397 Guard con
verter
.
1) Connect the reader to an RS-485 connector:
a. DATA0 to A;
b. DATA1 to B;
c. GND to G.
2) Connect BEEP and DATA0 terminals.Power on the reader.
3) Disconnect BEEP from DATA0. RS-485 link on the reader is now active until power off.
4) Launch the
R
ea
d
er
Conf
ig
software, choose
the converter COM port, then configure the
parameters.
6. SPECIFICATIONS
- Working frequency: .................................................................13.56 MHz;
- Supported tokens type: ..................................
Mifare Ultralight,
Mifare ID,
Mifare Standard (Classic) 1K
and 4K;
- Card/key fobs reading distance: .................................................
2
…6 cm;
- Output protocol: ......................iButton (Dallas Touch Memory), Wiegand;
- Line distance from controller:
via
iButton protocol: ................................................................up to 15 m;
via
Wiegand protocol: ...........................................................up to 100 m;
- Card reading status indication: ....visual bicoloured LED, audial buzzer;
- Indication control: .........................................................internal / external;
- Power
supply
voltage: ................................................................12 V DC;
- Current in Card Standby mode: ............................................up to 40 mA;
- Dimensions: ...................................................................85 x 44 x 18 mm.
7
. OPERATING CONDITIONS
Ambient temperature: -30…40°C.
Humidity: ≤ 98% at 25°C.
When operating under non-recommended conditions, device parameters can deviate from
specified values.
8
. PACKAGE CONTENTS
- Matrix
II
MF-I RFID
Reader:
...
1
-
Plugs
: ....................................
2
- Screws 3*30: .........................
.
2
- Wall plugs: ............................
.
2
Page 5
MATRIX II MF-I
www.ironlogic.
me