background image

5.3.  Configuration via RS-485 Link

Configuration via an RS-485 link requires 

R

eader 

Conf

ig

 software (see www.ironlogic.

me

 

website) and Z-397 Guard con

verter

.

  1)  Connect the reader to an RS-485 connector:
   

a.  DATA0 to A;

   

b.  DATA1 to B;

   

c.  GND to G. 

  2)  Connect BEEP and DATA0 terminals.Power on the reader. 
  3)  Disconnect BEEP from DATA0. RS-485 link on the reader is now active until power off.
  4)  Launch the 

R

ea

d

er 

Conf

ig

 software, choose

 

the converter COM port, then configure the  

   

parameters.

6.  SPECIFICATIONS

-  Working frequency: .................................................................13.56 MHz;
-  Supported tokens type:  ..................................

Mifare Ultralight,

 Mifare ID,

 

    

Mifare Standard (Classic) 1K

 and 4K;

-  Card/key fobs reading distance:  .................................................

2

…6 cm;

-  Output protocol:  ......................iButton (Dallas Touch Memory), Wiegand;
-  Line distance from controller:
 

via

 iButton protocol:  ................................................................up to 15 m;

 

via

 Wiegand protocol:  ...........................................................up to 100 m;

-  Card reading status indication:  ....visual  bicoloured LED, audial  buzzer;
-  Indication control:  .........................................................internal / external;
-  Power

 

supply

 

voltage:  ................................................................12 V DC;

-  Current in Card Standby mode: ............................................up to 40 mA;
-  Dimensions: ...................................................................85 x 44 x 18 mm.

7

. OPERATING CONDITIONS

Ambient temperature: -30…40°C. 
Humidity: ≤ 98% at 25°C.
When  operating  under  non-recommended  conditions,  device  parameters  can  deviate  from 
specified values.  

8

. PACKAGE CONTENTS

- Matrix

 

II 

MF-I RFID

 Reader: 

...

1

Plugs

:  ....................................

2

- Screws 3*30: .........................

.

2

- Wall plugs:  ............................

.

2

Page 5

MATRIX II MF-I

www.ironlogic.

me

Summary of Contents for Matrix II MF-I

Page 1: ...red place and fix it with screws 5 Close the reader case openings with plugs Fig 2 Note 1 Do not install readers closer than 10 cm one from another Note 2 To avoid electrical interference when connecting the reader to the controller a UTP cable is recommended such as CAT5e UTP cable see Fig 5 3 OPERATION Reader operation without external indication control 1 When power is supplied in standby mode ...

Page 2: ...ket terminals 1 Power supply 12 V 2 Common ground 3 DATA0 output 4 DATA1 output 5 LED G external control for green LED 6 LED R external control for red LED 7 BEEP external control for the buzzer To increase buzzer volume remove this sticker Reader ACS Controller iButton DS1990A emulation iButton One time transmission Common Common Common Fig 5 Connecting the reader to ACS controller CONNECTION LAY...

Page 3: ...R terminals 2 Power on the reader 3 If the LED is blinking red and asignal is sounding the reader is already in Protected Mode 4 If the LED is shining solid red touch the reader with the IronLogic Object card The reader changes LED colour to green and issues a beep for 1 second The Object card has now been stored into reader as a Master card 5 Power off the reader 4 1 2 Storing Object Cards Up to ...

Page 4: ...ls The reader will confirm the parameter choice and will switch into indicating parameter value 5 Indicating parameter value is similar to indicating parameter number but instead of LED flashing red it s flashing green Parameter values start with the current parameter value 6 To confirm the currently active parameter value connect LED G and GND terminals The new value is stored 7 Power off the rea...

Page 5: ...Mifare Ultralight Mifare ID Mifare Standard Classic 1K and 4K Card key fobs reading distance 2 6 cm Output protocol iButton Dallas Touch Memory Wiegand Line distance from controller via iButton protocol up to 15 m via Wiegand protocol up to 100 m Card reading status indication visual bicoloured LED audial buzzer Indication control internal external Power supply voltage 12 V DC Current in Card Stan...

Page 6: ...d production AVS LLC 7 Bobruiskaya street Saint Petersburg 195009 Russian Federation E mail marketing rfenabled com Phone 78122411853 78125421185 www ironlogic ru Authorized representative in the European Union SIA IRONLOGIC 79A Slokas iela LV 1007 Riga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me Page 6 MATRIX II MF I www ironlogic me The s...

Reviews: