IRIS IRIS-IO Quick Start Manual Download Page 4

© 2004-2010 of Ideus AB 

This radio equipment/product satisfies the significant requirements and other relevant stipulations of the “Guideline 1999/5/EG”

This document is copyrighted and all rights are reserved by Ideus AB. This document may not, in whole or in part, be copied, photocopied, or 

translated without the prior written consent of Ideus AB. This document contains proprietary information which is not to be used or brought to 

knowledge of a third part without the prior written consent of Ideus AB.

IO

IRIS-IO-Short manual-1a

www.irisnetwork.se 

TRL-Funksysteme GmbH 

Hans-Böckler-Strasse 5a 

D-63110 Rodgau-Jügesheim 

Germany

 

Telefon: +49 (0) 6106 / 60 08-0 

Telefax: +49 (0) 6106 / 60 08-33 

E-Mail: [email protected] 

Internet: www.trlfunk.de

Technical data

Radio communication:

Frequency:

433.050 - 434.775 MHz; 439.700 - 439.975 MHz

Channel pattern:

25 kHz channel spacing 

70 channels from 433.050 to 434.775 MHz 

(12 channels from 439.700 to 439.975 MHz 

for the Swedish market)

Sensitivity:

 -112 dBm @ 50 ohm

Modulation type:

FSK

Bit rate: 

4800 bit/s

Range:

> 1 km (in line of sight)

I/O:

Digital / analogue inputs

6

- Resolution

10 bits

- Range

0-30 VDC

- Input leakage

max 5 µA

Digital outputs

4  (V

max 

= 30 VDC) 

- Max output current

100 mA per output (resistive) 

Power supply:

Voltage:

8 – 35 VDC / 10 – 28 VAC

Power consumption (no active 

input or output pins) 

60 mA @ 12 VDC (transmitting)

Maximal power consumption

500 mA @ 12 VDC

Miscellaneous:

Size (without antenna):

23x82x91 mm

Temperature range:

0 – +55 °C

Factory settings

Radio communication:

Channel:

1

Message type:

Broadcast

I/O:

Inputs:

All digital

- Low

< 1 V

- High

> 2 V

Summary of Contents for IRIS-IO

Page 1: ...RIS IO so that the antenna is not shielded Avoid metal plating close to and between the antennas IRIS IO Product description IRIS IO can be used with different kind of electrical equipment for example relays switches sensors LED and machines with digital and analogue outputs and digital inputs The most common use of IRIS IO is a pair of IRIS IO that relays digital signals between two systems This ...

Page 2: ...alogue inputs have two different limits that can be detected and the value of the signal can be read The value can be scaled so that the value corresponds with for example a temperature from a sensor The radio channel can be changed if there is interference from other equipment All IRIS units must be set to the same channel to be able to communicate with each other The destination of a message can...

Page 3: ...the expected event Check that the event works and that it is connected to the right action The easiest way to check that the event works is to trigger another action For example set an output high and check the LED on the side of the IRIS IO It is always possible to change the configuration back to the original configuration using the IRIS configuration tool The original configuration file is found on ...

Page 4: ... 33 E Mail info trlfunk de Internet www trlfunk de Technical data Radio communication Frequency 433 050 434 775 MHz 439 700 439 975 MHz Channel pattern 25 kHz channel spacing 70 channels from 433 050 to 434 775 MHz 12 channels from 439 700 to 439 975 MHz for the Swedish market Sensitivity 112 dBm 50 ohm Modulation type FSK Bit rate 4800 bit s Range 1 km in line of sight I O Digital analogue inputs...