68
RCM-26 Remote Control Module
4 Appendix
4.1 Specifications/Technische Daten
NETWORK AND GENERAL FEATURES
Remote Control and Software
IRIS-Net™, Multiple PCs possible, MS Win-
dows 98, 2000, XP
Maximum Configuration
250 Amplifiers in total, 100 Amplifiers per
CAN bus, 1000 meter cable run
Supervised Amplifier Parameters Operation mode, temperature, output volta-
ge and current, impedance of connected
speakers, protection mode status, mains
voltage and current, power consumption, pi-
lot tone detection
Network Supervision
CAN bus failures, defective or missing am-
plifiers, bandwidth, failure protocol and mes-
saging
Audio Monitoring
All input and output signals
AUDIO SPECIFICATIONS
Analog Audio Input
2 audio inputs on internal slot connector,
pre-/post fader selectable
Input Level (nominal)
+6 dBu / 1.55 V
Input Level (max. before clip)
+21 dBu / 8.7 V
A/D Conversion
24 Bit linear, Sigma-Delta, 128 times over-
sampling
Digital Audio Input
AES3 (AES/EBU) format, XLR In/Thru con-
nectors
Input Sample Rates
32 kHz...192 kHz, internal Sample-Rate-
Converter
Audio Output
2 audio outputs on internal slot connector
Output Level (nominal)
+6 dBu / 1.55 V
Output Level (max. before clip) +21 dBu / 8.7 V
D/A Conversion
24 Bit, Sigma-Delta, 128 times over-sam-
pling
Monitor Outputs
2 x RJ-45 (REMOTE), electronically sym-
metric (Pins 7/8)
Summary of Contents for RCM-26
Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI RCM 26 Remote Control Module ...
Page 23: ...BEDIENUNGSANLEITUNG RCM 26 Remote Control Module ...
Page 45: ...MODE D EMPLOI RCM 26 Remote Control Module ...
Page 72: ...72 RCM 26 Remote Control Module 4 3 Dimensions Abmessungen ...
Page 73: ...RCM 26 Remote Control Module 73 ...
Page 74: ...Notes ...
Page 75: ...Notes ...