Routine maintenance:
EVERY 6 MONTHS: Cleaning
0
Remove the power supply to the preserving unit
and access the Sanigen
1
Release the external tab, holding the glass
cylinder still
2
Remove the external net from the glass cylinder,
paying attention not to break the glass
4
Check that the glass cylinder is not cracked.
If this is the case, the glass cylinder must be
replaced
7
Tighten the glass cylinder clockwise, always
acting on the red plastic base
5
Clean the glass cylinder with a damp cloth.
Remove any dust deposits carefully
6
8
Insert the external net, paying attention not
to overlap the internal net and keep a distance
of about 5 mm from the red base
9
Keeping the glass cylinder still, re-insert the
external tab checking that it is in good contact
with the external net
3
Tighten the glass cylinder anti-clockwise, always
acting on the red plastic base
Wash the external net in warm water, paying
attention not to deform it. Remove any dust deposits
carefully
Wash the external net in warm water, paying
attention not to deform it. Remove any dust deposits
carefully