Specifications are subject to change without notice

                                                                                     BLANKOM HDM-95xyC/T EN 2021 V1.0 

 

HDM-9500C or T 

 

 

Summary of Contents for BLANKOM HDM-9500C

Page 1: ...o Text Overlay insertions Ordering Info s C DVB C T DVB T output I ISDB Tb and A ATSC optional upon request E g HDM 9504C 4x HDMI IN DVB C OUT HDM 9508T 8x HDMI IN DVB T OUT HDM 9500C or T 6th Generation BLANKOM IPTV Headend Technology Broadcast grade high performance MPEG4 HD Encoder Modulator 4 or8 HDMI to RF output The HDM 95xy C T series products are BLANKOM s new breakthrough all in one devic...

Page 2: ...el Function PID remapping automatic or manually Generating of PSI SI tables automatically Modulation DVB C RF out 2 4 x RF DVB C out 2 4 carriers on combined IN Output Standard EN300429 ITU TJ 83A B DVB C Annex A B MER 40dB RF frequency 50 960MHz 1KHz step RF output level 25 1dBm 82 105 dBµV 0 1dBm Symbol Rate 5 0Msps 7 0Msps 1ksps stepping J 83A J 83B US Constellation 16 32 64 128 256QAM 64 256 Q...

Page 3: ... Text or Logo Pictures to the output Videos 14 Transport stream TS config Multiplexing 15 Output DVB T Modulator 23 Example for adding an IP MPTS to the Input for final remultiplexing 24 Installation Notes 29 Sources 29 Abbreviations from EN 300 468 V1 3 1 1998 02 31 ANNEX CATV Channel Plan CENELEC CATV channel plan 32 Appendix DB 33 Appendix A Product Disposal 35 Safety instructions 36 Sicherheit...

Page 4: ...Specifications are subject to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T APPLICATION EXAMPLE ...

Page 5: ...Ländern geltenden Vorschriften und Richtlinien für die Inbetriebnahme speziell für den Stromanschluß und alle mit den Produkten in Zusammenhang stehenden und geltenden Normen und Gesetze einzuhalten Remark All operating instructions published by us are intended for the antenna and IT specialist who has basic knowledge of reception network and system technology Compliance with all relevant regulati...

Page 6: ...put port carries DC Voltage 13V 18V max 400 mA By connecting a mains cable the device can become functional without any auxiliary appliances The power supply units are designed for the wide range of 100 230V AC a manual adjustment of the voltage is not necessary For some models the second power connector is feeding another independent power supply for internal redundancy For a maximum of redundanc...

Page 7: ...bit Ethernet NMS is 192 168 0 136 user password admin admin as defaults Please set your PC IP address into the same range but avoiding conflicts Then enter it We recommend to use Mozilla latest version and disable the popup blocker allow them But EDGE browser works as well You are entering the status page Getting basic information BTW It is always a good Idea to SAVE your config periodically ...

Page 8: ...Real time clock RTC will drift over the dates weeks slightly Below are 2 IP addresses as examples for German NTP servers you can use Daylight saving time like Summer Wintertime switching is not supported Please use CTRL V STRG V for pasting if you copy that from somewhere because some browser fileds do not be able to use the right mouse button and Insert from memory Reloading the webpage sometimes...

Page 9: ...Specifications are subject to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T UPDATING FIRMWARE ...

Page 10: ... finished START WITH THE ENCODINGS Note the APPLY Button bottom right The right side upper menu selects the encoder input and its sub menu s Everyone can be configured independently in CBR means Constant bitrate oriented encoding process VBR Variable so guess which is better Quality And which has lower latency NOTE The BITRATE needs to entered with the US notification as a Instead a ...

Page 11: ...he CODEC h 264 Downscaling can be chosen if needed Staying at AUTO is always a good choice AUDIO CODECS and sampling rates etc can be adjusted to your needs IN GENERAL THESE STEPS ARE RECOMMENDED 1 Connect your HDMI ports and configure your codecs and resolutions 2 Configure your OUTPUT DVB C T QAM COFDM Channels to your needed Data rates 3 Configure your Multiplexers Transport streams ...

Page 12: ...ect to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T Bitrate and values will be shown as graphics and numbers 50I interlaced with 50fps Example Switched from CBR to VBR encoding mode with high profile ...

Page 13: ...bject to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T As you can see The Stream is fluctuating more than with CBR This should be enabled when a DVB Modulator will be used to sync in the Multiplexer ...

Page 14: ...thout notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T OSD ON SCREEN DISPLAY EVERY ENCODER CAN ADD TEXT OR LOGO PICTURES TO THE OUTPUT VIDEOS Up to 6 different Layers per Video possible Or TEXT CAPTION can be inserted just play with it ...

Page 15: ...or every QAM Output channel the TS can be configured separately and independently But first the QAM DVB C output Values are the values which reflects to the max datarates in the TS You should be familiar with DVB C Frequency should fit into your existing cable TV if so Single Carriers of the 4 adjacent channels can be switched OFF Center frequency Bandwidth 8 MHZ in DVB C Europe not US ...

Page 16: ...city Stay at J 83A please B US Norm And Symbol Rate usually 6800 6850 or 6900 are OK SR 6750 or up to 6900 check Bandwidth now Much more Data can be pushed into this TS now 50 9 Mb s These 4 Multiplexed TS can be sent out as Multicast MPTS or RTSP on a particular port number to the DATA Port GbEthernet to feed other modulators in your network ...

Page 17: ... PID 8191dec to reach the Constant BitRate CBR 50 9Mb s here Modulator max data rate set If you like to send it to your network as VBR variable than check the Filter ON BACK TO THE TS CONFIG Every TS 1 4 can be separately selected to be configured TS1 goes to DVB C Channel 1 and so on CA Filter and PID Remap is not necessary for the encoder inputs Only might be necessary for external Inputs IP Inp...

Page 18: ... 1 2 into TS1 HDMI 3 4 into TS2 like above example Later on add IP stream inputs as well if there are some like from additional encoders i e our famous boxed encoder SDE 265 HD SDI source to IP output Select them than PARSE PROGRAMs to update the multiplexer TS Input values Than push it to the right side into the mux TSx ...

Page 19: ...djust every PIDs and parts of the TV Service by using your MOUSE button on the red highlighted Service A POPUP appears The Logical Channel Number LCN is a part of the NIT Network Information Table which you can use to pre select the TV set Channel Order if supported These Values should not be 2 same in one NIT ...

Page 20: ...ject to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T THE NIT CAN BE CONFIGURED IN GENERAL You should repeat this for every T stream QAM COFDM channel Even existing DVB Channels can be added here See ...

Page 21: ...P address and Port number chosen here adding editing deleting is self explaining If you have an MPTS coming in by IP you can forward single PIDs from it like EIT EPG Here only DATA IN GbE IP streams can be chosen Multicast by default needs IGMP settings for the Layer 3 Switch Unicast can be also used UDP or RTP IGMP snooping means check the GbE Switch as a forwarder for the Multicasts to be receiv...

Page 22: ...ot be used in the same subnet To be safe not to flood the network of the Management port NMS which always should be used separately from the streaming network Account here you can change your user password setting please write it down near the unit just in case another person needs to enter the encoder modulator in the future DOCUMENTATION is important Firmware update and Log can be used for their...

Page 23: ... the HDM 95xx is equipped with a COFDM Modular instead of DVB C the configuration is nearly similar because they are using the same Frequencies Bandwidth The difference is the Multicarrier COFDM modulation with following values to be set for maximum Datarate of 31 7Mb s in the TS 64QAM FFT2k Guard 1 32 8MHz per channel FEC7 8 ...

Page 24: ...V1 0 HDM 9500C or T Remark This screenshots are from the HDM 9416 Menu but Modulator part is nearly similar so do not wonder why herein ASI Input and USB player are on the left Input side EXAMPLE FOR ADDING AN IP MPTS TO THE INPUT FOR FINAL REMULTIPLEXING check and parse the input ...

Page 25: ...turb your complete TS which you push out to DVB T A good Idea is to reserve 10 15 NEGATIVE EXAMPLE OVERFLOW WILL APPEAR Of course the modulator Data rate is on its limit 31 7 Mb s and does not show more Deleting some in the mux let us good to go again Please be a bit patient with the settings and reactions takes some time Single channels can be switched OFF just in case there are occupied frequenc...

Page 26: ...Specifications are subject to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T Changed frequencies Measurements on 20dB output and level set 10dB before ...

Page 27: ...Specifications are subject to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T ...

Page 28: ...Specifications are subject to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T ...

Page 29: ...e outputs are decoupled from one another Thus the circuit does not have any effect on the functioning of the device Connections that are not required need not to be terminated except the unused cascaded trunk ports of the SAT multiswitches Suggestion For Ethernet cabling please use at least CAT 6E Ethernet cable for GigabitEthernet DSTP double shielded twisted pair for the streaming ports Note IPv...

Page 30: ...Specifications are subject to change without notice BLANKOM HDM 95xyC T EN 2021 V1 0 HDM 9500C or T We assume that the user is familiar with all abbreviations mentioned in this manual ...

Page 31: ...IEC International Electrotechnical Commission IRD Integrated Receiver Decoder ISO International Organization for Standardization LSB Least Significant Bit MJD Modified Julian Date MPEG Moving Pictures Expert Group NIT Network Information Table NVOD Near Video On Demand PAT Program Association Table PID Packet IDentifier PMT Program Map Table PSI Program Specific Information PSTN Public Switched Te...

Page 32: ... Superband channels S 11 230 237 233 50 231 25 236 75 40 630 638 634 00 631 25 636 75 S 12 237 244 240 50 238 25 243 75 41 638 646 642 00 639 25 644 75 S 13 244 251 247 50 245 25 250 75 42 646 654 650 00 647 25 652 75 S 14 251 258 254 50 252 25 257 75 43 654 662 658 00 655 25 660 75 S 15 258 265 261 50 259 25 264 75 44 662 670 666 00 663 25 668 75 S 16 265 272 268 50 266 25 271 75 45 670 678 674 0...

Page 33: ... 31 5 3E 04 17 77 31 75 7 08 6 7E 04 18 78 30 75 7 94 8 4E 04 19 79 29 75 8 91 1 1E 03 20 80 28 75 10 00 1 3E 03 21 81 27 75 11 22 1 7E 03 22 82 26 75 12 59 2 1E 03 23 83 25 75 14 13 2 7E 03 24 84 24 75 15 85 3 3E 03 25 85 23 75 17 78 4 2E 03 26 86 22 75 19 95 5 3E 03 27 87 21 75 22 39 6 7E 03 28 88 20 75 25 12 8 4E 03 29 89 19 75 28 18 0 011 30 90 18 75 31 62 0 013 31 91 17 75 35 48 0 017 32 92 1...

Page 34: ...1 49 109 0 25 281 84 1 059 50 110 1 25 316 23 1 333 51 111 2 25 354 81 1 679 52 112 3 25 398 11 2 113 53 113 4 25 446 68 2 660 54 114 5 25 501 19 3 349 55 115 6 25 562 34 4 216 56 116 7 25 630 96 5 308 57 117 8 25 707 95 6 683 58 118 9 25 794 33 8 413 59 119 10 25 891 25 10 591 60 120 11 25 1000 00 13 333 61 121 12 25 1122 02 16 786 62 122 13 25 1258 93 21 132 63 123 14 25 1412 54 26 604 64 124 15...

Page 35: ...ng dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et ou directives de respect de l environnement Renseignez vous auprès de l organisme compétent 경고 이 제품은 해당 국가의 관련 ...

Page 36: ...he immediate vicinity of sources of heat e g radiators other electrical devices fireplaces etc Risk of fire risk of electric shock danger of death Danger In order to prevent damage to the device as well as possible subsequent damage risk of fire devices intended for installation on the wall are only permitted to be installed on a level surface and not above head height Warning Only for optical tra...

Page 37: ...n the device or work on the connections Danger Repairs on the device may only be carried out by a specialist see EN 60065 observing the applicable VDE German Association for Electrical Electronic Information Technologies guidelines Danger Only use components of the same type and with identical technical properties for the repair Otherwise there is a risk of electric shock danger of death and risk ...

Page 38: ...t werden Es ist darüber hinaus unbedingt darauf zu achten daß Kabel nicht in die direkte Nähe von Wärmequellen verlegt werden z B Heizkörper andere Elektrogeräte Kamin etc Brandgefahr Gefahr durch elektrischen Schlag Gefahr Um sowohl Beschädigungen am Gerät als auch mögliche Folgeschäden Brandgefahr zu vermeiden dürfen für Wandmontage vorgesehene Geräte nur auf einer ebenen Grundfläche montiert we...

Page 39: ... Spannung angeschlossen und betrieben werden Dies gilt auch wenn Sie das Gerät reinigen oder an den Anschlüssen arbeiten Gefahr Reparaturen am Gerät sind ausschließlich vom Fachmann siehe EN 60065 unter Beachtung der geltenden VDE Richtlinien durchzuführen Gefahr Verwenden Sie nur Bauteile des gleichen Typs und mit identischen technischen Eigenschaften für die Reparatur andernfalls droht Gefahr ei...

Page 40: ...Netzgerät dürfen keine mit Flüssigkeit gefüllten Gegenstände gestellt werden No liquid filled items may be placed on top of the power supply unit Das Netzgerät darf nicht Tropf oder Spritzwasser ausgesetzt sein The power supply unit must not be exposed to dripping or splashing water Der Netzstecker muss ohne Schwierigkeiten zugänglich und benutzbar sein The mains plug must be easily accessible and ...

Page 41: ...HDM 9500C or T CONTACT IRENIS GmbH Hauptstr 29 31171 Nordstemmen Germany Phone 49 5069 4809781 IRENIS technical hotline VoIP 49 5069 4399 860 or 8601 Managing Director Dipl Ing Murad Önol Commercial Register HRB 206370 District Court Hildesheim Web www blankom de E Mail info blankom de ...