Page 1: ... Using Intended Use The iReliev Pain Relief Patch is intended for temporary relief of pain associated with sore and aching muscles in the upper and lower extremities arm and or leg due to strain from exercise or normal household and work activities ...

Page 2: ...iReliev Pain Relief Patch 7 1 Components and Functional Parts of the Unit 2 Prior to Use 3 Installing Changing the Battery 4 Use and Functions 5 After Use Cleaning and Maintenance 11 1 Device 2 Electrode Placement of Electrode 12 Troubleshooting Guide 13 Technical Specifications 14 Warranty 15 2 ...

Page 3: ...the following conditions are present Do not use this device if you have a cardiac pacemaker implanted defibrillators or any other implanted metallic or electronic device Do not use this device if you have undiagnosed chronic pain Warnings for proper use and safety If you are under the care of a Physician consult with your Physician before using this device The long term effects of this device are ...

Page 4: ... use the Pain Relief Patch over or close to sores Do not use this device while sleeping Do not use if you feel numbness Do not use these devices in or close to water Use the Pain Relief Patch only on normal healthy clean and dry skin Do not use it on open wounds or rashes or over swollen red infected or inflamed skin If you have ever had back surgery consult your Physician before using this device...

Page 5: ... you have some other health problem You should know the reason and source of your pain before using these devices Do not solely rely on the treatment of this device for pain The safety of using the Pain Relief Patch during pregnancy or birth has not been established The effectiveness of this device depends greatly on a person s individual physical condition It may not always be effective for every...

Page 6: ... reaction It is not considered a skin irritation and it will normally disappear within 30 minutes after the electrodes are removed If the redness does not disappear after 30 minutes from the removal of electrodes do not use the stimulator again until after the excessive redness has disappeared Turn off your device if the stimulation feels unpleasant or does not provide pain relief Keep this device...

Page 7: ...d and work activities 1 Components and Functional Parts of the Unit UP ON DOWN OFF On intensity Up Switch Function display LED Green Back side battery compartment Off intensity Down Switch Electrode pad Adverse Reactions Skin irritation and burns under the pads have been reported by some people who have applied electronic stimulators to their skin You should stop using the device and should consul...

Page 8: ...ress the DOWN OFF button to switch the unit off 2 2 Position the iReliev Pain Patch device and electrode pad so that the plugs and jacks are aligned on a flat surface Then press down until electrode pad is completely snapped in Do not remove the clear plastic shield from electrode until the unit is ready to be placed on the body 2 3 Ensure the skin is clean and thoroughly dry wherever you intend t...

Page 9: ...UP button again the device starts to work at the lowest level of intensity The device has 10 levels of intensity for strength of treatment Select these intensity levels by simply pressing ON UP button the appropriate number of times 4 4 The device has an automatic shut off function which switches it off automatically after 20 minutes of treatment 4 5 Treatment may be discontinued at any time by pr...

Page 10: ...n by taking the electrode pad at the edge and pulling carefully Do not grasp at the unit Replace the electrode pad onto the clear plastic shield 5 3 Never remove the unit when it is switched on 5 4 Notes for safety and care Do not switch on the unit before the electrode pad is positioned on the body Keep the electrode pad from direct sunlight Take care that no water penetrates the unit 10 ...

Page 11: ...r single person use only Clean the adhesive surface after use to achieve better adhesion Moisten the gel with a drop of water and allow it to dry briefly Then stick the electrode back on the protective film The length of time the electrodes remain usable depends on their storage skin type and use Store the electrode in a cool dry place 11 o Replace electrode when it is no longer tacky or show crac...

Page 12: ...Placement of Electrode 12 ...

Page 13: ...e apply Device Replace battery Check electrode pads and replace if necessary Replace battery Check electrode pads and replace if necessary Re apply device CAUSE No battery in the device or battery is dead Battery not inserted correctly Device not switched on Insulating film has not be removed Battery is low Electrode pad is dirty Device not applied properly Battery is dead Electrode pad dirty or s...

Page 14: ...rom 0 60mA 20 Pulse Width 150 250uS Pulse Rate 30 60Hz Power Source 1 Lithium Coin Cell battery CR2032 Automatic Shut Off 20 minutes Operating Conditions 50 F 10 C to 104 40 C 40 90 max Relative humidity Storage Condition 14 F 10 C to 140 60 C 30 95 max Relative humidity Weight 0 5 oz 12 3 g battery included Dimensions 2 3 in x 1 2 in x 0 5 in 59 x 30 x 12 15 mm 14 ...

Page 15: ...e from defects in workmanship and materials at the time of delivery The warranty does not apply to damage resulting from failure to follow the operating instructions accidents abuse alterations or disassembly by unauthorized individuals ExcelHealth or distributor reserves the right to replace or repair the device at its discretion Return to ExcelHealth Inc 102 Trewin School Rd Park City MT 59063 2...